Technical Data
3A0537M
21
See
Models
on page 3 for your pump part number.
Viscount II Motor, 3000cc Lower
Fluid Outlet Pressure
8
15
23
38
30
psi
MPa, bar
cycles per minute
gpm
liters/minute
30
60
91
151
181
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
E
R
U
S
S
E
R
P
DI
U
L
F
1.4, 14
0.7, 7
A
B
C
46
212
2.1, 21
Hydraulic Oil Consumption
gpm
l/min.
cycles per minute
gpm
liters/minute
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
N
OI
T
P
M
U
S
N
O
C
LI
O
CI
L
U
A
R
D
Y
H
30
15
45
60
53
121
8
15
23
38
30
30
60
91
151
181
46
212
53
121
1.0, 10
0.35, 3.5
1.8, 17.5
Viscount II Motor, 4000cc Lower
F
L
UID P
R
E
SSURE
HYDRA
ULIC OIL
CONSUMPTION
0
B
A
C
10
21
31
52
200
1.4, 14
400
2.8, 28
100
0.7, 7
300
2.1, 21
gpm
l/min
60
Hydraulic Oil Consumption
Fluid Outlet Pressure
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
cycles per minute
cycles per minute
42
10
21
31
52
60
42
12
45
10
38
8
30
6
23
4
15
2
7.6
0
gpm
liters/minute
48
181
40
151
32
121
24
91
16
60
8
30
0
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
gpm
liters/minute
48
181
40
151
32
121
24
91
16
60
8
30
0
psi
MPa, bar
Key:
A
10.3 MPa, 103 bar (1500 psi) hydraulic pressure
B
7.2 MPa, 72.4 bar (1050 psi) hydraulic pressure
C
4.1 MPa, 41 bar (600 psi) hydraulic pressure
The shaded area within the table shows the recommended