![Graco Twistork 224854 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/graco/twistork-224854/twistork-224854_instructions-parts-manual_2253106006.webp)
Installation
6
308175T
Install the Agitator
1. Install the agitator on the container cover by
screwing the helix through the drum bung hole and
screwing the agitator housing into the bung hole.
Refer to
.
2. Position the air motor so the air line can easily be
attached to the needle valve's 1/8 npt inlet, without
obstructing any other system components. See F
3. Attach a bleed-type air shutoff valve (SV) for main
air shutoff. Optionally, attach an air line disconnect
valve. Order part number 208536, coupler and
169969 fitting, quick disconnect air line fitting.
4. Attach the air line between the needle valve's
1/8 npt inlet and the 1/8 npt air supply manifold
outlet.
Grounding
Check your local electrical code for detailed grounding
instructions for your area and type of equipment.
Remove the grounding screw (A) and lockwasher (B).
See F
. 3. Secure the ground wire terminal (C) to the
agitator with the screw and lockwasher. Connect the
other end of the ground wire to a true earth ground.
Order part number 222011, ground wire and clamp.
NOTICE
Keep the agitator tightly mounted to the drum bung to
prevent damage to the threads from vibration.
When using a modified drum, check that there is no
interference between the base of the drum and the
shaft of the agitator.
F
IG
. 2: Agitator Installation
Muffler
Needle Valve
1/8 npt Air Inlet
The equipment must be grounded to reduce the risk
of static sparking. Static sparking can cause fumes to
ignite or explode. To reduce the risk of static sparking,
all electrically conductive objects or devices in the
spray area must be properly grounded.
F
IG
. 3: Ground the Agitator
A
B
C
1089a