Warnings 

4

308175T

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system 
component. See 

Technical Specifications

 in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See 

Technical 

Specifications

 in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For 

complete information about your material, request Safety Data Sheets (SDSs) from distributor or 
retailer.

Do not leave the work area while equipment is energized or under pressure.

Turn off all equipment and follow th

Pressure Relief Procedure

 when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine 
manufacturer’s replacement parts only.

Do not alter or modify equipment. Alterations or modifications may void agency approvals and create 
safety hazards.

Make sure all equipment is rated and approved for the environment in which you are using it.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or 
swallowed.

Read Safety Data Sheets (SDSs) to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

PERSONAL PROTECTIVE EQUIPMENT

Wear appropriate protective equipment when in the work area to help prevent serious injury, including 
eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment includes but is not 
limited to:

Protective eyewear and hearing protection.

Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

WARNING

Содержание Twistork 224854

Страница 1: ...industrial coatings For professional use only 100 psi 0 7 MPa 7 bar Maximum Working Pressure See page 2 for model information Important Safety Instructions Read all warnings and instructions in this...

Страница 2: ...7 Check Fluid Viscosity 7 Maintenance 8 Flush the Air Motor 8 Agitator Blades 8 Lubricate the Air Motor 8 Service 9 Align the Outlet Housing 9 Parts 10 Model 224854 Twistork Helix Agitator 10 Model 23...

Страница 3: ...and gasoline Do not plug or unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggeri...

Страница 4: ...y approvals and create safety hazards Make sure all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for...

Страница 5: ...t numbers listed below 110223 1 4 npt f x 1 4 npt f 110224 3 8 npt f x 3 8 npt f 113333 3 8 npt m x 3 8 npt f Install an air line filter AF to remove harmful dirt and moisture from the air supply To o...

Страница 6: ...rical code for detailed grounding instructions for your area and type of equipment Remove the grounding screw A and lockwasher B See FIG 3 Secure the ground wire terminal C to the agitator with the sc...

Страница 7: ...d possible To stop the agitator close the bleed type air shutoff valve SV or close the needle valve 11 Stop the agitator and disconnect the air line before removing it from the container Check Fluid V...

Страница 8: ...rease the material conductivity with additives Use liquids with a high conductivity 1000 pS m Lubricate the Air Motor If an air line lubricator AL is not installed the air motor must be manually lubri...

Страница 9: ...the following Replacing the outlet housing 4 Replacing the air motor 1 Repairing the agitator 1 Place the agitator in a vertical position and loosen the three outlet housing screws 17 See Parts page 1...

Страница 10: ...ue to 80 100 in lbs 9 11 3 N m 1 2 Apply medium grade sealant to external threads Torque to 34 40 in lbs 4 4 5 N m Be sure air motor shaft bottoms out in mounting hole before tightening 3 Align as ins...

Страница 11: ...ch 1 2 20 X 0 5 3 4 224876 HOUSING outlet carbon steel 1 6 224393 HELIX agitator 1 7 187054 PLUG fluid tube 1 8 101946 PIN cotter 1 9 111312 O RING Fluoroelastomer 1 10 112364 SCREW set socket 1 4 20...

Страница 12: ...que to 80 100 in lbs 9 11 3 N m 1 2 Apply medium grade sealant to external threads Torque to 34 40 in lbs 4 4 5 N m Be sure air motor shaft bottoms out in mounting hole before tightening 3 Align as in...

Страница 13: ...HOUSING outlet carbon steel 1 6 224393 HELIX agitator 1 7 187054 PLUG fluid tube 1 8 101946 PIN cotter 1 9 111312 O RING Fluoroelastomer 1 10 112364 SCREW set socket 1 4 20 UNC 3A 2 11 206264 VALVE n...

Страница 14: ...Dimensions 14 308175T Dimensions 6 96 in 177 mm To bottom of threads 1 8 npt 2 11 1 2 npt 32 67 in 830 mm 0908C...

Страница 15: ...104 F 1 C Ta 40 C Wetted Parts Model 224854 Carbon Steel Fluoroelastomer Acetal Model 235534 304 316 Stainless Steel Fluoroelastomer Acetal Noise dBa Pressure Power Noise level at 100 psi normal load...

Страница 16: ...n material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRA...

Отзывы: