background image

All written and visual data contained in this document reflects the latest product information available at the time of publication. 

Graco reserves the right to make changes at any time without notice.

Sales Offices: 

Minneapolis, Detroit

International Offices: 

Belgium Korea, Hong Kong, Japan

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441

www.graco.com

Printed in USA  309476B Revised 01/2003

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material 
and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, 
extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the 
equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in 
accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty 
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of 
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with 
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance 
of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of 
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned 
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will 
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED 
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy 
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or 
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT 
MANUFACTURED BY GRACO

. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to 

the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these 
warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or 
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the 
negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, 
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la 
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite 
de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

TO PLACE AN ORDER,

 contact your Graco distributor, or call this number to identify the distributor closest to you: 

1-800-367-4023 Toll Free

612-623-6921

612-378-3505 Fax

Содержание TRITON 1030HP

Страница 1: ...1030HP Diaphragm Pump Part No 233750 Series A 3 1 Ratio Air Operated Double Diaphragm Pump with BSPP Fittings Part No 233751 Series A 3 1 Ratio Air Operated Double Diaphragm Pump with npt Fittings 0...

Страница 2: ...6 Repair the Air Valve 18 Replace the Ball Check Valves 20 Replace the Cylinder and Piston Seals 22 Parts 24 Technical Data 26 Performance Charts 27 Dimensions 29 Wall Mount Hole Pattern 29 Graco Stan...

Страница 3: ...nd solvent manufacturer s warnings Do not use hoses to pull equipment Route hoses away from traffic areas sharp edges moving parts and hot surfaces Do not expose Graco hoses to temperatures above 82 C...

Страница 4: ...wer cords or turn lights on or off in the spray area TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin inhaled or swallowed Kno...

Страница 5: ...port must point down and the outlet port must point up Use 5 8 in lag screws or bolts for mounting Wall Mount Installation 1 Wall Mount Kit 245875 is available See FIG 1 2 Be sure the wall can suppor...

Страница 6: ...line accessories 2 Install a grounded flexible air hose A between the accessories and the pump air inlet See Technical Data on page 26 to determine the air inlet size of your pump Use a minimum 13 mm...

Страница 7: ...luid Supply G Fluid Drain Valve H Fluid Shutoff Valve J Fluid Line K Mounting Bracket L Internal Air Relief Valve M Muffler N Air Line Quick Disconnect Coupler P Pump Air Piston R Pump Diaphragms S Pu...

Страница 8: ...No 238909 Air and fluid hoses Use only electrically conductive hoses Air compressor Follow manufacturer s recommen dations Fluid supply drum Follow your local code All solvent pails used when flushin...

Страница 9: ...en the fluid shutoff valve H 7 With the pump air regulator C closed open the bleed type master air valve B 8 If the fluid hose has a dispensing device hold it open while continuing with the following...

Страница 10: ...ure all threaded connections are tight and leak free 3 Check and re torque all screws and fasteners at least every two months Re torque the fluid cover screws first followed by the manifold screws Pre...

Страница 11: ...Maintenance 309476B 11...

Страница 12: ...Sticky or leaking check valves Clean or replace balls 56 and seats 53 See page 20 Ruptured diaphragm 14 Replace See page 16 Do not exceed maximum air input pressure Restricted exhaust Remove restrict...

Страница 13: ...t Ball Check Diaphragm Air Piston Inlet Ball Check Outlet Manifold Tube Fluid Inlet Inlet Manifold Tube Outlet Ball Check Diaphragm Inlet Ball Check Diaphragm Shaft Optional Fluid Outlet Air Valve Air...

Страница 14: ...Troubleshooting 14 309476B...

Страница 15: ...s immediately to prevent additional damage Tools Required 4 5 6 8 and 10 mm allen wrenches 13 mm open end wrench 28 mm open end wrench or adjustable wrench two flat blade screwdrivers 2 Phillips screw...

Страница 16: ...he tube hous ings 4 attached The arrow must point toward the top of the pump and the air inlet 40 must be to the right of the cover 1 Torque the screws 31 to 20 N m 15 ft lb 4 Lubricate the o rings 13...

Страница 17: ...Repair 309476B 17 FIG 6 Replace the Diaphragms 13 12 13 14 13 12 13 14 31 31 1 40 1 2 3 Lubricate Torque to 12 N m 8 8 ft lb 1 2 2 1 1 1 1 2 TI1959A 4 4...

Страница 18: ...ll the o rings 19 20 on the three bearings 18 Install the bearings in the center housing 5 cylinder inner cover 6 and cylinder outer cover 11 Secure with the clips 21 2 Install the carriage 45 in the...

Страница 19: ...17 Check that the felt strips 71 are in place on the inside of the top 67 and bottom 66 covers Install the covers The hole for the air inlet fitting must align with the port in the center housing 5 Ti...

Страница 20: ...seal 59 and seal 58 4 Install the inlet tube assembly Torque the screws 38 to 10 N m 7 4 ft lb Ball Check Valve Repair Kit 243154 is available Parts included in the kit are marked for example 56 For t...

Страница 21: ...309476B 21 FIG 8 Replace the Ball Check Valves 12 38 2 65 57 56 55 54 59 53 65 57 56 53 59 58 3 38 12 4 38 58 53 56 57 65 59 65 57 56 55 54 38 4 59 53 59 59 Torque to 10 N m 7 4 ft lb 1 1 1 1 1 TI196...

Страница 22: ...ing 5 Do not lose the o ring 28 Reassembly 1 Install the o rings 42 28 in the housing 5 2 Install the o rings 22 25 on the inner cover 6 3 Install the o ring 23 packing 26 and quad ring 32 on the pist...

Страница 23: ...nstall the flat seals 55 59 and the other ball check parts see page 20 17 Install the tube assemblies Torque the screws 38 to 10 N m 7 4 ft lb FIG 9 Replace the Cylinder and Piston Seals 38 37 36 35 3...

Страница 24: ...47 45 67 5 13 12 13 38 2 65 57 56 55 54 59 53 1 31 65 57 56 53 59 58 3 38 13 12 13 68 66 68 70 7 22 22 11 20 18 19 21 14 4 38 10 9 58 59 53 56 57 65 31 1 59 65 57 56 55 54 53 21 19 18 20 29 30 17 46 2...

Страница 25: ...21 117021 CLIP c spring 3 22 O RING nitrile 2 23 O RING nitrile 1 24 15A031 TUBE air valve 1 25 117006 O RING nitrile 1 26 PACKING 1 27 117023 PIN spring 1 28 117012 O RING Viton 1 29 117028 SCREW so...

Страница 26: ...cle Operating temperature range 10 80 C 50 176 F Dry suction lift 2 5 m 8 2 ft Wet suction lift 6 7 m 22 ft Air inlet size Model 233750 1 2 BSPP f Model 233751 1 2 npt f Fluid inlet size Model 233750...

Страница 27: ...8 0 6 0 4 0 2 7 6 15 1 22 7 30 2 37 8 45 4 52 9 60 5 68 0 75 6 83 2 Key A 0 6 MPa 6 bar 88 psi B 0 4 MPa 4 bar 60 psi C 0 2 MPa 2 bar 30 psi Fluid Flow Air Consumption A B C C B A 2 4 6 8 10 12 14 16...

Страница 28: ...PerformanceCharts 28 309476B...

Страница 29: ...146 mm 5 7 in 160 mm 6 3 in 213 mm 8 4 in M8 Mounting Holes Air Inlet see page 26 for sizes Fluid Inlet see page 26 for sizes Fluid Outlet see page 26 for sizes TI1964A TI1963A 100 mm 4 in 260 mm 10...

Страница 30: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANT...

Отзывы: