Component Identification
Install
Install
Install the
the
the Remote
Remote
Remote Switch
Switch
Switch (Optional)
(Optional)
(Optional)
The remote switch is an additional accessory kit and
does not come with models 25A300 and 25A304.
The kit part number is 17G554. See manual 3A3112
for remote switch installation and replacement.
NOTE:
NOTE:
NOTE: Use zip-tie (Z) to install the remote switch
to the hose or pole spray applicator (follow the
illustrations below). The remote switch will fit on
hoses/applicators sized .75 in. up to 1.25 in.
Prime
Prime
Prime with
with
with Material
Material
Material
NOTICE
NOTICE
NOTICE
Loading material into a dry system will cause the material
to stick to internal components and cure, causing
damage and requiring replacement of those parts. To
prevent material curing in system, never load material
into a dry system.
The applicator must be removed before priming.
Always push out any remaining water into a waste
container before circulating material. Always circulate
clean material back into the hopper for several cycles
before beginning to spray.
1.
Prime the system with water. See
Prime with Water, page 16
.
2.
Mix the material. See
Mix the Material, page 17
.
3.
Turn the flow adjustment knob (H)
counterclockwise until it stops.
4.
Remove the applicator.
5.
Fill the clean hopper with material to be sprayed.
6.
Place the hose outlet in a waste container.
7.
Turn the motor power switch (S) to ON.
8.
Turn the flow adjustment knob (H) clockwise
slowly to increase pressure until water is purged
out and a steady stream of material flows from
the applicator.
NOTICE
NOTICE
NOTICE
To prevent damage to pump seals caused by
cavitation, run the pump slowly until the system is
primed.
9.
To stop dispensing, turn adjustment knob (H)
counterclockwise until it stops.
10. Install applicator.
NOTE:
NOTE:
NOTE: For EIFS finish coats, before installing the
applicator, prime the larger ID hose, then install
and prime the transition fitting and whip hose.
11. Recirculate several cycles of material to make
sure the material is flowing properly.
12. Turn the flow adjustment knob (H)
counterclockwise to stop the pump.
13. Install the air line and a tip onto the applicator
(see applicator manual). The system is now
primed and ready to spray.
3A3437F
11