System
System
System Components
Components
Components
* Required system components.
To avoid tipping over, ensure cart is on a flat and
level surface. Failure to do so could result in injury
or equipment damage.
*** Bleed
Bleed
Bleed Type
Type
Type Master
Master
Master Air
Air
Air Valve
Valve
Valve (B)
(B)
(B)
• Be sure the valve is easily accessible from the
applicator.
• Required in your system to relieve air trapped
between it and the air motor when the valve is
closed.
– Open to supply air to the motor.
– Close to shut off air to the motor and bleed any
trapped air from the motor.
*** Air
Air
Air Pressure
Pressure
Pressure Relief
Relief
Relief Valve
Valve
Valve (C)
(C)
(C)
Automatically opens to relieve air pressure if set
pressure exceeds preset limit.
Air
Air
Air Filter
Filter
Filter (D)
(D)
(D)
Removes harmful dirt and water from compressed
air supply.
Air
Air
Air Regulator
Regulator
Regulator Adjustment
Adjustment
Adjustment (F)
(F)
(F)
Adjusts air pressure to the motor and fluid outlet
pressure of pump. Read air pressure on gauge (E).
*** Zero
Zero
Zero Cavity
Cavity
Cavity Relief
Relief
Relief Valve
Valve
Valve (J)
(J)
(J)
Open valve to relieve pressure if pump or hose
packout occurs. Close valve when spraying.
NOTICE
NOTICE
NOTICE
To prevent material hardening in zero cavity relief
valve, flush the valve after every time it is used.
See
.
To avoid skin injection and splashing, never
open a camlock hose or applicator fitting
while there is pressure in the fluid line. See
Pressure Relief Procedure, page 15
12