Service
12
310538N
Service
Prepare to Service Automatic
Dispense Valve
If the unit is hot, determine whether or not you can
service the unit after it has cooled down. Some
materials, like polyurethanes, may cure permanently
when cooled and exposed to air, preventing you from
disassembling the dispense valve. If you are working
with such a material, service the unit while the material
is at a temperature where the material is soft enough to
work with. If the material can be reheated at a later time,
you can service the unit after it has cooled, reheating
the material as necessary.
Perform this procedure before servicing the automatic
dispense valve.
1. Relieve the system pressure.
2. Make sure material flow has been shut off.
3. Make sure system air has been shut off.
4. Remove power from the automatic dispense valve.
5. If the material in the dispense valve can be
reheated, wait for the dispense valve to cool thor-
oughly before servicing it.
If the material in the dispense valve cures perma-
nently when cooled and/or exposed to air, service
the unit while the material is at a temperature where
the material is soft enough to work with.
WARNING
To reduce the risk of serious injury, whenever you are
instructed to relieve pressure, always follow the
WARNING
HOT SURFACE AND FLUID HAZARD
The material and equipment will be hot!
To
reduce the risk of injury, wear eye protection,
gloves and protective clothing when
servicing this dispensing system component.
Содержание Therm-O-Flow Series
Страница 19: ...Parts 310538N 19 Parts Model 194485 Warm 275 F 135 C max Automatic Dispense Valve with Snuff Back ...
Страница 21: ...Parts 310538N 21 Parts Model 918483 Therm O Flow Automatic Dispense Valve with Snuff Back ...
Страница 23: ...Parts 310538N 23 Parts Model 918512 Ambient Therm O Flow Automatic Dispense Valve with Snuff Back ...
Страница 25: ...Parts 310538N 25 Parts Model 918639 Therm O Flow Automatic Dispense Valve with Snuff Back ...
Страница 27: ...Parts 310538N 27 Parts Model 243694 Therm O Flow Automatic Dispense Valve ...
Страница 29: ...Parts 310538N 29 Parts Model 297266 Automatic Hot Melt Swirl Dispense Valve ...
Страница 31: ...Parts 310538N 31 Parts Model 243695 Therm O Flow Automatic Dispense Valve ...
Страница 33: ...Parts 310538N 33 Parts Model 243696 Therm O Flow Automatic Dispense Valve with Snuff Back ...
Страница 35: ...Parts 310538N 35 Parts Model C27340 Ambient Therm O Flow Automatic Dispense Valve Double Acting ...
Страница 37: ...Parts 310538N 37 Parts Model C34068 Warm Automatic Dispense Valve Double Acting ...
Страница 39: ...Parts 310538N 39 Parts Model C34079 Therm O Flow Automatic Dispense Valve Double Acting ...
Страница 41: ...Parts 310538N 41 Parts Model C50592 Therm O Flow Automatic Dispense Valve Double Acting ...
Страница 45: ...Dimensions 310538N 45 Dimensions ...
Страница 46: ...Dimensions 46 310538N ...