Troubleshooting
10
310538N
Troubleshooting
Some solutions require disassembling the automatic dispense valve. Always relieve system pressure before
performing these procedures.
See PARTS section for the parts that need to be serviced.
WARNING
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow
(page 11).
Problem
Cause(s)
Solution(s)
Air leaks from automatic dispense
valve
Loose air connections
Check air connections.
Worn o-rings
Replace o-rings (90) and (100) in cylinder
base.
Worn ring
Replace ring (110) in cylinder base.
Material leaks from front of
automatic dispense valve
Seal, spacer or retaining ring is worn
Replace rod seal (150), spacer (160),
and retaining ring (170).
Obstruction inside dispense valve
Remove seat adapter (10). Check and
replace if necessary, rod seal (150),
spacer (160), and retaining ring (170).
Worn needle
Check and replace needle (140), if
necessary.If replacing needle, you must
disassemble dispense valve.
Worn seat (Base seal models)
Check and replace seat (10) if necessary.
Material leaks from automatic dispense
valve body
Seal not installed correctly
Check seal (70) and replace if necessary.
Seal is worn
Automatic dispense valve
does not shut off
Loose air connections
Check air connections.
Worn needle-seal interface
Check and replace, if necessary, needle
(140), rod seal (150), spacer (160), and
retaining ring (170).
If replacing needle, you must disassemble
dispense valve
Automatic dispense valve
does not shut off
Worn spring-piston interface
Disassemble dispense valve. Check
and replace, if necessary, needle (140),
and spring (370).
Automatic dispense valve
does not shut off
Spring broken or not installed correctly
Disassemble dispense valve. Check
and replace, if necessary, needle (140),
and spring (370).
Automatic dispense valve does not
heat material
Loose heater wires
Check and reconnect wire connections.
Loose sensor wires
Check and reconnect wire connections.
Heater unit failed
Replace heater. See page 17.
Sensor failed
Replace sensor. See page 17.
Temperature controller failed
Replace temperature controller.
No power to heating circuitry
Apply power to heating circuitry.
Содержание Therm-O-Flow Series
Страница 19: ...Parts 310538N 19 Parts Model 194485 Warm 275 F 135 C max Automatic Dispense Valve with Snuff Back ...
Страница 21: ...Parts 310538N 21 Parts Model 918483 Therm O Flow Automatic Dispense Valve with Snuff Back ...
Страница 23: ...Parts 310538N 23 Parts Model 918512 Ambient Therm O Flow Automatic Dispense Valve with Snuff Back ...
Страница 25: ...Parts 310538N 25 Parts Model 918639 Therm O Flow Automatic Dispense Valve with Snuff Back ...
Страница 27: ...Parts 310538N 27 Parts Model 243694 Therm O Flow Automatic Dispense Valve ...
Страница 29: ...Parts 310538N 29 Parts Model 297266 Automatic Hot Melt Swirl Dispense Valve ...
Страница 31: ...Parts 310538N 31 Parts Model 243695 Therm O Flow Automatic Dispense Valve ...
Страница 33: ...Parts 310538N 33 Parts Model 243696 Therm O Flow Automatic Dispense Valve with Snuff Back ...
Страница 35: ...Parts 310538N 35 Parts Model C27340 Ambient Therm O Flow Automatic Dispense Valve Double Acting ...
Страница 37: ...Parts 310538N 37 Parts Model C34068 Warm Automatic Dispense Valve Double Acting ...
Страница 39: ...Parts 310538N 39 Parts Model C34079 Therm O Flow Automatic Dispense Valve Double Acting ...
Страница 41: ...Parts 310538N 41 Parts Model C50592 Therm O Flow Automatic Dispense Valve Double Acting ...
Страница 45: ...Dimensions 310538N 45 Dimensions ...
Страница 46: ...Dimensions 46 310538N ...