Errors
Errors
Errors
The Errors screens store a maximum of 200 errors.
See
. Download the errors list in the USB
logs. See
Appendix B — USB Data, page 104
.
Diagnostic
Diagnostic
Diagnostic---A
A
A
This screen shows details of various items to aid
in troubleshooting the system. This screen can be
hidden by de-selecting “Enable Diagnostics Screen”
on the System 3 screen. The flow rate updates every
15–20 seconds with average flow rate over the last
15–20 seconds.
Note
Diagnostic-B shows information for an
optional secondary system.
The following information is displayed.
Diagnostic
Diagnostic
Diagnostic Data
Data
Data
A Current Draw
B RTD Reading
C Duty Cycle
CAN:
CAN:
CAN: 24 VDC power supply voltage reading (18–28
VDC)
DI:
DI:
DI: System Digital Inputs
0: Drum Empty
1: Drum Low
2: Pump Cycle Switch Up
3: Pump Cycle Switch Down
DO:
DO:
DO: System Digital Outputs
0: Pump Solenoid
1: Not Used
2: Not Used
3: Not Used
ISO
ISO
ISO DI:
DI:
DI: Customer Digital Inputs
See
.
ISO
ISO
ISO DO:
DO:
DO: Customer Digital Outputs
See
.
Fan:
Fan:
Fan: current to fan
Heat
Heat
Heat Soak:
Soak:
Soak: set time for platen to heat after the platen
has reached set temperature.
Life
Life
Life Cycles:
Cycles:
Cycles: total number of pump cycles over life of
system
MZLP
MZLP
MZLP 1:
1:
1: temperature on MZLP 1
• 32–160°F(0–71°C)
Pump
Pump
Pump Sol:
Sol:
Sol: Current draw of pump solenoid
• (0 mA - off)
• (150-250 mA - on)
Pump
Pump
Pump CPM:
CPM:
CPM: Pump cycles per minute.
USB
USB
USB DL%:
DL%:
DL%: Percentage complete, only applies when
downloading USB data. 5 downloads will occur.
Weight:
Weight:
Weight: Weight of material dispensed over life of
system
XFMRTemp:
XFMRTemp:
XFMRTemp: Temperature of transformer
temperature sensor
Setup
Setup
Setup Screens
Screens
Screens
Note
It is important to set all settings in the System
screens correctly to ensure optimal system
performance.
334130D
99
Содержание Therm-O-Flow 200
Страница 48: ...Repair Figure 28 48 334130D...
Страница 56: ...Repair Figure 34 Inside of Electrical Control Enclosure 56 334130D...
Страница 59: ...Electrical Schematics 400V 400V 400V 3 3 3 Phase 50 Phase 50 Phase 50 Hz Hz Hz 334130D 59...
Страница 60: ...Electrical Schematics 400 600VV 400 600VV 400 600VV 3 3 3 Phase 60 Phase 60 Phase 60 Hz Hz Hz 60 334130D...
Страница 61: ...Electrical Schematics AWB AWB AWB and and and MZLP 1 MZLP 1 MZLP 1 334130D 61...
Страница 63: ...Electrical Schematics MZLP MZLP MZLP Zones Zones Zones 334130D 63...
Страница 67: ...Parts Electrical Electrical Electrical Module Module Module 334130D 67...
Страница 68: ...Parts 68 334130D...
Страница 94: ...Accessories and Kits 94 334130D...