
Error
Error
Error Codes
Codes
Codes
There are three types of errors that can occur. Errors
are indicated on the display as well as by the optional
light tower.
Alarms are indicated by
. This condition indicates
a parameter critical to the process has reached a
level requiring the system to stop. The alarm needs
to be addressed immediately.
Deviations are indicated by
. This condition
indicates a parameter critical to the process has
reached a level requiring attention, but not sufficient
enough to stop the system at this time.
Advisories are indicated by
. This condition
indicates a parameter that is not immediately critical
to the process. The advisory needs attention to
prevent more serious issues in the future.
To acknowledge the error, press
.
The third digit, or sometimes the last digit of the error
code, indicates which unit the error is active on. The
“
” (star) character indicates the code applies to
multiple system components.
Third
Third
Third or
or
or Last
Last
Last Digit
Digit
Digit “““
★
”””
Codes
Codes
Codes Relates
Relates
Relates To:
To:
To:
A
Unit A
B
Unit B
The last digit of the error code indicates which
system component the error applies. The “#” (pound)
character indicates the code applies to multiple
system components.
Last
Last
Last Digit
Digit
Digit “#”
“#”
“#”
Codes
Codes
Codes Relates
Relates
Relates To
To
To
System
System
System Component:
Component:
Component:
1
MZLP 1
2
MZLP 2
3
MZLP 3
5
MZLP 5
6
MZLP 6
7
MZLP 7
V
AWB Unit A
W
AWB Unit B
X
Daughter Board Unit A
Y
Daughter Board Unit B
The last digit of the error code indicates which
heat zone the error applies. The “_” (underscore)
character indicates the code applies to multiple
system components.
Last
Last
Last Digit
Digit
Digit “_”
“_”
“_”
Codes
Codes
Codes Relates
Relates
Relates To
To
To Heat
Heat
Heat
Zone:
Zone:
Zone:
1
Zone 1
2
Zone 2
3
Zone 3
4
Zone 4
5
Zone 5
6
Zone 6
7
Zone 7
8
Zone 8
9
Zone 9
A
Zone 10
B
Zone 11
C
Zone 12
D
Pump
E
Platen
38
334130D
Содержание Therm-O-Flow 200
Страница 48: ...Repair Figure 28 48 334130D...
Страница 56: ...Repair Figure 34 Inside of Electrical Control Enclosure 56 334130D...
Страница 59: ...Electrical Schematics 400V 400V 400V 3 3 3 Phase 50 Phase 50 Phase 50 Hz Hz Hz 334130D 59...
Страница 60: ...Electrical Schematics 400 600VV 400 600VV 400 600VV 3 3 3 Phase 60 Phase 60 Phase 60 Hz Hz Hz 60 334130D...
Страница 61: ...Electrical Schematics AWB AWB AWB and and and MZLP 1 MZLP 1 MZLP 1 334130D 61...
Страница 63: ...Electrical Schematics MZLP MZLP MZLP Zones Zones Zones 334130D 63...
Страница 67: ...Parts Electrical Electrical Electrical Module Module Module 334130D 67...
Страница 68: ...Parts 68 334130D...
Страница 94: ...Accessories and Kits 94 334130D...