Connect
Connect
Connect PLC
PLC
PLC
A PLC can control and monitor all items
shown in the Customer Digital Inputs and
Outputs shown on the Diagnostics screen. See
.
When the PLC has control of the system:
• Functionality is restricted from the ADM
• Automatic crossover is disabled. Rely on the PLC
and machine state indicators to know when to
cross over using the I/O.
Table
Table
Table 5
5
5 Customer
Customer
Customer Input
Input
Input
Signal
Signal
Signal
No.
No.
No.
Unit
Unit
Unit A
A
A
Description
Description
Description
1
Heat On Request
Turn on the Heat
2
Setback Request
Put the Unit in
Setback
3
Pump On Request
Turn on the Pump
4
PLC Control Request
(input applies to
primary to unit A
only)
Control the primary
and secondary TOF
systems from the
PLC instead of the
ADM
Table
Table
Table 6
6
6 Customer
Customer
Customer Output
Output
Output
Signal
Signal
Signal
No.
No.
No.
Unit
Unit
Unit A
A
A or
or
or B
B
B
Description
Description
Description
1
Run State Bit Low
See Run State Chart
2
Run State Bit High
See Run State Chart
3
Error State Bit Low
See Error State
Chart
4
Error State Bit High
See Error State
Chart
Table
Table
Table 7
7
7 Output
Output
Output Error
Error
Error States
States
States
Error
Error
Error State
State
State Bit
Bit
Bit
High
High
High
Error
Error
Error State
State
State Bit
Bit
Bit
Low
Low
Low
0
0
Machine is
good, no errors
are present
0
1
Active Unit
Drum Low
1
0
Active Unit
Drum Empty
1
1
Alarm Present
in System
Table
Table
Table 8
8
8 Output
Output
Output Run
Run
Run States
States
States
Run
Run
Run State
State
State Bit
Bit
Bit
High
High
High
Run
Run
Run State
State
State Bit
Bit
Bit
Low
Low
Low
0
0
Pump Off/ Heat
Off
0
1
Pump Off/ Heat
On
1
0
Pump Off/ Heat
At Temp
1
1
Pump On/ Heat
At Temp
Note
All outputs are normally open when power is
OFF. For error (alarm) output, the contacts
close when an alarm occurs. For all others,
contacts close.
Note
The TOF system ships with two screw
terminal connectors that plug into MZLP
connectors H1 and H2. Connectors are
located in a bag on the inside of the electrical
enclosure. To replace the connectors, order
kit 24P176.
1.
Turn main power switch off.
2.
Open the electrical enclosure door.
3.
Route I/O cables through strain relief.
4.
Remove power from the PLC.
334130D
25
Содержание Therm-O-Flow 200
Страница 48: ...Repair Figure 28 48 334130D...
Страница 56: ...Repair Figure 34 Inside of Electrical Control Enclosure 56 334130D...
Страница 59: ...Electrical Schematics 400V 400V 400V 3 3 3 Phase 50 Phase 50 Phase 50 Hz Hz Hz 334130D 59...
Страница 60: ...Electrical Schematics 400 600VV 400 600VV 400 600VV 3 3 3 Phase 60 Phase 60 Phase 60 Hz Hz Hz 60 334130D...
Страница 61: ...Electrical Schematics AWB AWB AWB and and and MZLP 1 MZLP 1 MZLP 1 334130D 61...
Страница 63: ...Electrical Schematics MZLP MZLP MZLP Zones Zones Zones 334130D 63...
Страница 67: ...Parts Electrical Electrical Electrical Module Module Module 334130D 67...
Страница 68: ...Parts 68 334130D...
Страница 94: ...Accessories and Kits 94 334130D...