Air Flow Sensor Replacement
310717E
25
Air Flow Sensor Replacement
For 120 V sprayer use Sensor Replacement Kit 287326.
Disassembly
First read and follow instructions in the Before perform-
ing any service on sprayer section, page 8.
Then remove hopper, front and back covers, page 8.
Remove hose extension and RotoFlex HD Pump
assembly from frame, page 10.
1.
Disconnect all wire
connections.
2.
Rotate coun-
ter-clockwise to
remove sensor from
manifold.
Reassembly
1.
Rotate new sensor
from kit clockwise,
all the way into
opening in Relief
Valve housing.
Lightly tighten nut.
2.
Reconnect all wires.
3.
Replace RotoFlex
HD Pump and hose
extension, page 10.
4.
Replace back and
front covers and
hopper. See
Removing and
Replacing Hopper,
Front and Back Cover, page 8.
If you are only replacing the sensor, you do not
have to remove the motor first.