Installation
313444E
5
Installation
NOTE:
Reference letters used throughout these instruc-
tions refer to the reference letter provided on the Com-
ponent Identification page 4.
•
Mount panel in a dry location near the bearing that
is being serviced.
•
Line length from the air/oil mixing blocks (K) to the
spindle ranges from 2 to 50 feet (0.61 m to 15.24
m).
•
Mount panel using 3/8 inch (0.375 mm) diameter
bolts. Panel mounting dimensions are provided in
the Technical Data section of this manual, page 13.
Grounding
The equipment must be grounded. Grounding reduces
the risk of static and electric shock by providing an
escape wire for the electrical current due to static build
up or in the event of a short circuit.
Electrical Connections - All
Models
1. Verify all power to the system is disconnected.
2. Remove enclosure cover from top of pump.
3. Install electrical cable through connector located on
right side of electrical enclosure.
4. Referring to the wiring diagram for your model (115
and 230 VAC or 24 VDC) in F
. 1, connect Pump
Power leads to their respective terminals within the
enclosure.
F
IG
. 1
Wiring Diagram: 115 VAC & 230 VAC Units
Wiring Diagram: 24 VDC Units