Set System Parameters
3A0294J
59
Set Pump Runaway Error
1.
Navigate to setup screen 7.
2.
Press
to access fields to make changes.
3.
Press
to navigate to the pump runaway
cycle rate field.
4.
Press
and
to increment or decre-
ment to the desired cycle rate. Graco recommends
setting the cycle rate to 60 or less. Choose a value
that is just above the maximum cycle rate of the
application.
5.
Press
to save the set cycle rate.
6.
Press
to exit edit mode.
Set Maintenance Parameters
Set the amounts of material moved through the pump
and dosing valve that will result in a maintenance advi-
sory or alarm.
1.
Navigate to setup screen 8.
2.
Press
to access fields to make changes.
3.
Press
to navigate to the maintenance
setpoint field.
4.
Press
and
to increment or decre-
ment to the desired amount of material that will
result in an advisory when the total volume dis-
pensed exceeds the maintenance setpoint.
5.
Press
to save this amount.
6.
If an advisory occurs, press
to navigate to the
total volume dispensed field. Clear the field to reset
the advisory.
7.
Press
to exit edit mode.
Maintenance
Total Volume
Dispensed
Setpoint
Содержание SmartWare 262370
Страница 77: ...Parts 3A0294J 77 Parts Kits 262370 and 262372 30 33 28 29 29 28 34 5 2 29 28 4 31 28 29 32 3b 36 38 41 37 3a 3c...
Страница 80: ...Parts 80 3A0294J Kit 262371 25 4 5 28 24 23 27 23 24 26 24 23 2 3c 24 23 3a 3b 30 32 33 31...
Страница 81: ...Parts 3A0294J 81 Kit 262371 continued 17 20 21 18 19 35 47 44 37 37 37 42 38 40 46 39 43 36 45 48 14...
Страница 84: ...Parts 84 3A0294J Kit 262373 continued 39 40 41 42 42 43 44 45 46 47 49 42 50 47 52 53 15...
Страница 86: ...Parts 86 3A0294J Kit 262374 19 20 16 17 18 22 23 4 3a 5 2 24 25 27 29 28 32 3b 3c...
Страница 87: ...Parts 3A0294J 87 Kit 262374 continued 33 34 35 36 36 37 38 39 40 41 43 36 44 43 46 47 13...
Страница 92: ...Parts 92 3A0294J...
Страница 107: ...Technical Data 3A0294J 107...