Setup
312372E
3
Setup
1. Install an air pressure regulator on gun air
supply line to control air pressure.
2. Install a shutoff valve downstream of the air
regulator to shut off gun air.
3. Connect a clean, dry, filtered air supply to
air inlet fitting (13). Connect other end to
shutoff valve.
4. Install fluid filter into fluid inlet.
5. Screw on gravity cup.
6. Remove gravity cup cover and fill cup with
solvent to flush if this is first time using
equipment. (See
Flushing
, page 5.)
7. After flushing, fill cup with fluid and attach
cover.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on
skin, inhaled, or swallowed.
• Read MSDS’s to know the specific hazards of the fluids you are using.
• Store hazardous fluid in approved containers, and dispose of it according to appli-
cable guidelines.
• Always wear impervious gloves when spraying or cleaning equipment.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in
the operating area of the equipment to help protect you from serious injury, including
eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes
but is not limited to:
• Protective eyewear
• Clothing and respirator as recommended by the fluid and solvent manufacturer
• Gloves
• Hearing protection
WARNING
Reference numbers and letters in paren-
theses in the text refer to numbers and
letters in the illustrations.
F
IG
. 1
8-2
5
13
1
Содержание Sharpe Finex FX1000