Repair
Disconnect Piston Pump
1. Follow
2. Disconnect inflatable seal supply air and air assist
supply air.
3. Remove two clamps (12) holding the tie rods (2) to
the ram plate. Remove gaskets (7).
4. Remove nut (4) and washer (3) holding the air
motor connecting rod (10) to the tie beam (114).
5. Open main air valve (BA). Set the director valve
(BC) to UP to raise the ram. Set the director valve to
neutral. Close main air valve (BA).
6. To remove the pump from the ram plate, remove
clamp (13) and gasket (8). Carefully lift the pump up
and away from the plate, using two people if
needed.
NOTE:
See your piston pump manual and air motor manual
for cleaning, repair, and parts information.