background image

Pressure Relief Procedures

Pressure

Pressure

Pressure Relief

Relief

Relief Procedures

Procedures

Procedures

Callout letters in these procedures correspond with
control panel information in the operation manual.

Ram

Ram

Ram Pressure

Pressure

Pressure Relief

Relief

Relief Procedure

Procedure

Procedure

Follow the Ram Pressure Relief
Procedure whenever you see this
symbol.

This equipment stays pressurized until pressure
is relieved manually. To help prevent serious
injury from pressurized fluid, such as skin injection
or splashing in the eyes or on skin, follow the
Pressure Relief Procedure when you stop pumping
and before you clean, check, or service the
equipment.

1.

For exposed manual pneumatic control:

a.

Close the air motor slider valve (AH) and the
main air slider valve (AA).

NOTE

NOTE

NOTE: Both are relieving air valves.

b.

Set the ram director valve (AD) to DOWN.
The ram will slowly move to the bottom of
its travel.

c.

Jog the ram director valve (AD) up and down
to bleed air from ram cylinder.

2.

For enclosed pneumatic control:

a.

Close the air supply valve.

b.

Toggle the ram position control switch (BC)
up and down to bleed air from the ram
cylinders. The ram will slowly move to the
bottom of its travel.

3.

For electro-pneumatic control:

a.

Stop evacuation activity.

b.

If used, open all user-supplied system fluid
drain valves that are downstream of the
pump.

c.

Navigate to the System Configuration
screen. Press the Shutdown/Depressurize
icon. When pressed, a pop-up will appear
indicating the system is depressurizing. The
ram will slowly move.

d.

The pop-up will indicate if depressurization
was completed successfully. Close the air
supply valve (CE).

NOTE:

NOTE:

NOTE: A pressure alarm will appear after
supply air is removed.

Pump

Pump

Pump Pressure

Pressure

Pressure Relief

Relief

Relief Procedure

Procedure

Procedure

Follow the Pump Pressure Relief
Procedure whenever you see this
symbol.

This equipment stays pressurized until pressure
is relieved manually. To help prevent serious
injury from pressurized fluid, such as skin injection
or splashing in the eyes or on skin, follow the
Pressure Relief Procedure when you stop pumping
and before you clean, check, or service the
equipment.

1.

Using pump operation controls on the control
panel, remove incoming air to the pump motor.

2.

Open a pressure relief valve on the outlet line.

8

3A5404F

Содержание SaniForce 3A5402

Страница 1: ...explosive explosive explosive atmospheres atmospheres atmospheres or or or hazardous hazardous hazardous locations locations locations See See See Configuration Configuration Configuration Matrix Matr...

Страница 2: ...mps Instructions and Parts 3A5564 SaniForce 6 1 Sanitary Pumps Instructions and Parts 3A5799 SaniForce 12 1 Sanitary Pumps Instructions and Parts 3A5999 SaniForce High Sanitation Diaphragm Pumps Opera...

Страница 3: ...ON EXPLOSION HAZARD HAZARD HAZARD Flammable fumes such as solvent and paint fumes in work work work area area area can ignite or explode Paint or solvent flowing through the equipment can cause static...

Страница 4: ...dispensing device hose leaks or ruptured components will pierce skin This may look like just a cut but it is a serious injury that can result in amputation Get Get Get immediate immediate immediate s...

Страница 5: ...only for its intended purpose Call your distributor for information Route hoses and cables away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses...

Страница 6: ...e Frame Frame Pump Pump Pump Ram Ram Ram Plate Plate Plate Seal Seal Seal Style Style Style SDU SDU SDU A A A Stainless Steel 01 01 01 5 1 Double Ball A A A 20 Inflatable Seal for use with 21 5 to 23...

Страница 7: ...umatic SST static AE AE AE SST Ram piston rods 6 6 6 Exposed pneumatic carbon steel inflatable 7 7 7 Exposed pneumatic carbon steel static Not ATEX Not intended for use in explosive or hazardous envir...

Страница 8: ...le the ram position control switch BC up and down to bleed air from the ram cylinders The ram will slowly move to the bottom of its travel 3 For electro pneumatic control a Stop evacuation activity b...

Страница 9: ...Cylinder Cylinder Cap Cap Cap 1 Perform the Pump Pressure Relief procedure 2 Perform the Ram Pressure Relief procedure and turn off facility air to the system 3 Disconnect the air cylinder air lines...

Страница 10: ...p assembly a Install inner o ring 7 and outer o ring 8 on the cap 3 b Install o ring 6 in bushing 4 c From the side of the cap with the bolt flange insert bushing into cap d From the smaller diameter...

Страница 11: ...nual for more information Air leaks around cylinder rod Worn rod seal Replace Ram air pressure is too high Decrease Seal not fully inflated Increase seal air pressure check for seal air leak Use the f...

Страница 12: ...ect fluid line Turn on air If pump starts the fluid line is clogged Worn throat packing Replace throat packing Pump operates but output low on both strokes Damaged cylinder seal Replace seal Pump inle...

Страница 13: ...Parts Parts Parts Parts 3A5404F 13...

Страница 14: ...Parts 14 3A5404F...

Страница 15: ...Parts 3A5404F 15...

Страница 16: ...Parts 16 3A5404F...

Страница 17: ...Parts 3A5404F 17...

Страница 18: ...2 3 17V700 25D947 CAP 2 4 17V713 25E543 BUSHING ram top 2 5 17R789 25E543 RETAINER spiral 2 6 17R802 25E543 O RING 322 2 7 120998 25E543 O RING 2 8 514316 25E543 O RING 4 9 17R791 25E543 RETAINER 4 10...

Страница 19: ...C31 6 1 3 1 approval per EN10204 2004 25N008 12 1 2 1 approval per EN10204 2004 25N008C31 12 1 3 1 approval per EN10204 2004 101 PUMP double ball 25N010 5 1 2 1 approval per EN10204 2004 25N010C31 5 1...

Страница 20: ...all pump 0 17W711 5 1 double ball pump 1 17W712 12 1 priming piston pump 1 17W713 6 1 priming piston pump 1 111 17W714 SETSCREW only used if Ref 110 is used 1 112 16F384 FITTING 1 2 npt x 1 2 PTC 1 11...

Страница 21: ...oroprene 25P318 inflatable EPDM WIPER 608193 Buna N wiper seal for 21 5 in diameter drum 202 18A057 Buna N wiper seal for 22 5 in diameter drum 1 203 16D169 GASKET 2 204 118598 CLAMP sanitary 2 205 16...

Страница 22: ...6 x 1 in 4 311 CONTROL air refer to separate air controller manual 1 25E038 25E030 Manual pneumatic exposed static seal 25D266 25E650 Manual pneumatic exposed inflatable seal 25C543 25P255 Enclosed ma...

Страница 23: ...cessory code code code AC AC AC Kit Kit Kit Part Part Part Number Number Number 25E153 25E153 25E153 Painted carbon steel dolly for drums up to 24 inch diameter Load rating of 2000 pounds Kit contains...

Страница 24: ...279 Kg Electro Electro Electro pneumatic pneumatic pneumatic Control Control Control Panel Panel Panel Enclosure Type 4X IP65 Voltage 100 240 VAC Phase 1 Frequency 50 60 Hz Maximum Current 1 3 A NOTE...

Страница 25: ...Notes Notes Notes Notes 3A5404F 25...

Страница 26: ...ARRANTY WARRANTY WARRANTY AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AN...

Отзывы: