Installation
3A6831G
11
0750 (7.5 in) Pneumatic Motor Minimum Gas Pressure
psi (MPa, bar)
Outlet Pressure psi
(MPa, bar)
3/4 Inch
Fluid Plunger
1 Inch
Fluid Plunger
0 (0, 0)
15.0 (0.1, 1.0)
15.0 (0.1, 1.0)
500 (3.4, 34.5)
15.0 (0.1, 1.0)
15.0 (0.1, 1.0)
1000 (6.9, 68.9)
15.0 (0.1, 1.0)
16.4 (0.1, 1.1)
1500 (10.3, 103.4)
15.0 (0.1, 1.0)
24.6 (0.2, 1.7)
2000 (13.8, 137.9)
20.0 (0.1, 1.4)
32.8 (0.2, 2.3)
2500 (17.2, 172.4)
25.0 (0.2, 1.7)
41.0 (0.3, 2.8)
3000 (20.7, 206.8)
30.0 (0.2, 2.1)
49.2 (0.3, 3.4)
3500 (24.1, 241.3)
35.0 (0.2, 2.4)
57.4 (0.4, 4.0)
4000 (27.6, 275.8)
40.0 (0.3, 2.8)
65.6 (0.5, 4.5)
4500 (31.0, 310.3)
45.0 (0.3, 3.1)
73.8 (0.5, 5.1)
5000 (34.5, 344.7)
50.0 (0.3, 3.4)
82.0 (0.6, 5.7)
5500 (37.9, 379.2)
55.0 (0.4, 3.8)
90.2 (0.6, 6.2)
6000 (41.4, 413.7)
60.0 (0.4, 4.1)
98.4 (0.7, 6.8)
6100 (42.1, 420.6)
61.0 (0.4, 4.2
100.0 (0.7, 6.9)
6500 (44.8, 448.2)
65.0 (0.4, 4.5)
7000 (48.3, 482.6)
70.0 (0.5, 4.8)
7500 (51.7, 517.1)
75.0 (0.5, 5.2)
8000 (55.2, 551.6)
80.0 (0.6, 5.5)
8500 (58.6, 586.1)
85.0 (0.6, 5.9)
9000 (62.1, 620.5)
90.0 (0.6, 6.2)
9500 (65.5, 655.0)
95.0 (0.7, 6.6)
10000 (68.9, 689.5) 100.0 (0.7, 6.9)
For applications where the exhaust is ported to
a pressurized location, compute the difference
between the inlet and outlet pressures to get
the pneumatic pressure to be used in the
above tables. Minimum pressure differential is
15 psi (0.1 MPa, 1.0 bar).