Operation Using a Programmable Logic Controller (PLC)
Network
Network
Network Output
Output
Output Data
Data
Data Map
Map
Map (Read
(Read
(Read Only)
Only)
Only)
Network
Network
Network
Output
Output
Output ID
ID
ID
Modbus
Modbus
Modbus
Register
Register
Register
Parameter
Parameter
Parameter Name
Name
Name
Data
Data
Data Type
Type
Type
Units
Units
Units
Range
Range
Range
1 = Pump Off
2 = Color Change
3 = Color Change: Purge A
4 = Color Change: Purge B
5 = Color Change: Fill
6 = Mix Fill
7 = Mix
8 = Mix Idle
9 = Purge A
10 = Purge B
11 = Standby: Mix Ready
12 = Standby: Fill Ready
13 = Standby: Mix Not Ready
14 = Standby: Alarm
15 = Line Filling/Flushing
16 = Pump Prime/Flush
17 = Maintenance/Calibration
0000
41000
Current System Mode
uint32
NONE
18 = Mix: Solvent Push
0 = No Events
0001
41002
Event Flag
uint32
NONE
1 = New Event
0002
41004
Actual Mix
Flow/Pressure
uint32
cc/min
PSI
1 – 1600
0003
41006
Actual Mix Ratio
uint32
NONE
0 – 5000
0004
41008
Actual Mix Potlife
Remaining
uint32
sec
0 – 59940
0 = Gun not triggered
0005
41010
Gun 1 Trigger Status
uint32
NONE
1 = Gun triggered
0 = Off
1 = Standby
2 = Busy
3 = Flushing
0006
41012
Pump 1 Status
uint32
NONE
4 = Priming
0 = Off
1 = Standby
2 = Busy
3 = Flushing
0007
41014
Pump 2 Status
uint32
NONE
4 = Priming
0008
41016
Pump 1 Material
uint32
NONE
0 – 40, 61
0009
41018
Pump 2 Material
uint32
NONE
0 – 40, 61
3A4486D
31