Recalibrate Meter-based System
309908G
31
Set Meter K-factor
1.
Open main air valve to start unit. Allow time for sys-
tem to boot up and display ratio setting.
4.
Turn key to change k-factor (left to decrease, right to
increase).
5.
Release
to set k-factor.
7.
Component B dispensed volume will display. Com-
pare displayed volume with actual volume in con-
tainer B.
a.
For no change, press
, then release.
b.
To change display, press and hold
. Turn key
to change display to match actual volume (left to
decrease, right to increase). Release
.
Ratio tolerance default value for meter-based sys-
tems is 5%. To change to a customized value, use
accessory Data Download Kit 248403 (IS) or
248404 (Non-IS) and follow instructions in manual
309623.
See manual 308778 for meter k-factor values.
2.
Turn function knob to A
or B
.
3.
Hold down
(continue to hold until k-factor is set
in step 5). After 5 seconds, the default k-factor dis-
plays.