background image

ProMix Web Interface 

8

311191C

Web Navigation Screens

From the main screen (see F

IG

. 7) the operator can 

select Setup, Reports, or Software Resets.

Setup

Download setup values - saves the ProMix 
configuration to the PC. This file can be opened and 
edited using Microsoft Excel, or used to set up multiple 
systems.

Restore setup values - allows files to be uploaded and 
restored to the ProMix.

Display setup values - indicates what values are 
currently being used for the system. Allows the operator 
to verify that the right values are being used. See F

IG

. 8.

Download custom language - saves the current 
system language to the PC. This file is opened and a 
custom language added to the B column of the Excel 
file. See F

IG

. 9.

 Custom languages are limited to Ascii and Ascii 

extended characters and a maximum of 32 characters. 
Save the Excel file as a tab delineated file for uploading 
purposes.

Restore custom language - allows the custom lan-
guage file to be uploaded to the ProMix.

End current job - ends a job and adds material to 
usage report.

Software Resets

Install EasyKey software - downloads the Graco 
provided software to the PC (approximately 5 minutes). 
Once complete the control panel will be reprogrammed 
from the EasyKey.

Reset settings - places system back to factory default 
mode.

Reset password - clears password if lost or forgotten.

Advanced Configuration

To change IP settings, type in 192.168.0.1\config.html. 
Or use the freeware configuration program available 
from 

www.lantronix.com/device-networking/utili-

ties-tools/device-installer.html

.

F

IG

. 8 Display Set up

Data for Display setup values

TargetRatio0          10
TargetRatio1          10
TargetRatio2          10
TargetRatio3          10
TargetRatio4          10
TargetRatio5          10
TargetRatio6          10
TargetRatio7          10

F

IG

. 9 Download Custom Language

Save In

bin

File Name:

Files of Type:

Download custom language

Combined_2_00_006.REC

vssver.scc

All Files

Combined_2_00_007.rec

vssver.scc

DisplayBoard_2_00_

Combined_2_00_008.rec

DisplayBoard_2_00_004.rec

DisplayBoard_2_00_005.rec

DisplayBoard_2_00_006.rec

DisplayBoard_2_00_007.rec

Содержание ProControl

Страница 1: ... proportioners Important Safety Instructions Read all warnings and instructions in this manual Save these instructions 311191C Software Instructions ProMix Auto ProControl Network Communications or Local Network Direct Local Network TI7232A ...

Страница 2: ... influence of drugs or alcohol Do not exceed the maximum working pressure or temperature rating of the lowest rated system component See Technical Data in all equipment manuals Use fluids and solvents that are compatible with equipment wetted parts See Technical Data in all equipment manuals Read fluid and solvent manufacturer s warnings For complete information about your material request MSDS fo...

Страница 3: ...the program to operate correctly Follow the screen link to Java version 1 4 2 09 or newer Or enter http java sun com j2se 1 4 2 download html and select Download J2SE JRE The file is approxi mately 15 MB Manual Language Manual Language 311191 English 311277 Chinese 311273 French 311278 Korean 311274 Spanish 311297 Italian 311318 German 311298 Dutch 311276 Japanese If the Graco program will not sta...

Страница 4: ...ble from the PC plugs into the Pro Mix Web Interface connection A crossover cable is provided with all systems See FIG 1 and page 10 Local Network Connection Hardware and Software Configuration Hardware Patch cables are used to connect each ProMix unit to the local network and to the ProMix Web connection A on the EasyKey panel See FIG 2 FIG 1 Network Selection Laptop PC Non hazardous Area Only Ea...

Страница 5: ...r computer a On your computer click on the Start button to open the menu then click on Control Panel b See FIG 3 Double click on Network Connec tions Double click on Local Area Connection to open the Local Area Connection Status window Click on Properties to open the Local Area Con nection Properties window See FIG 4 FIG 3 Assign IP Address on Computer ...

Страница 6: ...0 3 f Type in the following Subnet mask 255 255 255 0 g Click on OK to accept the change and close the Internet Protocol TCP IP Properties window h Click on OK to close the Local Area Connection Properties window i Close the Local Area Connection Properties window and Network Connections window 2 On the EasyKey go to Advanced Screen 4 and write down the IP number assigned to that EasyKey 1 99 FIG ...

Страница 7: ...tp 192 168 0 1 3 Click Enter 4 Select yes when security screen appears 5 Main software screen appears See FIG 7 If Cannot Read Firmware appears check for loose hardware connections If Java script needs to be loaded appears fol low the screen link to install this freeware FIG 6 Java Internet Options Use smooth scrolling HTTP 1 1 settings Use HTTP 1 1 Use HTTP 1 1 through proxy connections Java Sun ...

Страница 8: ...ustom lan guage file to be uploaded to the ProMix End current job ends a job and adds material to usage report Software Resets Install EasyKey software downloads the Graco provided software to the PC approximately 5 minutes Once complete the control panel will be reprogrammed from the EasyKey Reset settings places system back to factory default mode Reset password clears password if lost or forgot...

Страница 9: ... jobs from the display Clear error log deletes the errors from the display FIG 10 Display Material Usage report Data for Display material usage report Start Time 09 23 2005 Material Usage End Time Recipe 1 2 3 09 22 2005 0 A cc 0 0 0 0 0 B cc 10 22 15 16 33 57 FIG 11 Display Job Log FIG 12 Display Error Log Data for Display job log Job 001 002 003 004 005 Date 23 Sep 2005 23 Sep 2005 23 Sep 2005 2...

Страница 10: ...s C and spread apart 6 Install the Modbus TCP converter 1 next to the power supply PS 7 Position DIN rail end blocks C against the Mod bus TCP converter 1 and power supply PS to prevent them from moving Cable Connections FIG 14 shows a completed Modbus TCP Kit Installation 1 Connect the 24 volt power supply with wire mod bus TCP harness 5 2 Install second part of harness to J11 on display board to...

Страница 11: ...rk to PC with DeviceInstaller 3 Run DeviceInstaller program A freeware configuration program is available from www lantronix com device networking utili ties tools device installer html 4 Change IP Address from Default setting 192 168 02 a Run DeviceInstaller b Click Search c Select device d Click Assign IP Select and assign specific IP address i Input address ii Enter subnet mask 255 255 255 0 ii...

Страница 12: ...its 0 2 Active Component shown on run screen Y 40023 SetupOpen 16 bits 0 1 1 if in setup screens 0 Run Screens Y 40026 ccNewRecipe 16 bits 0 60 New recipe when RobotDigitalIn recipe bits are changed Y 40027 Opmode 16 bits 0 99 0 MIX 1 PURGE 2 STANDBY 3 COLOR CHANGE 4 CC_MIX 5 CC_PURGE 6 METER CAL 7 FLOWCAL 8 AUTODUMP 40029 DesFlow 16 bits 0 9999 Flow Command Input Analog Setup Variables Address Va...

Страница 13: ...32 bits 0 9999 1 Lock setup screens on display 41508 DoseSize 16 bits 0 3 0 15cc 1 25cc 2 50cc 41509 StationNum 16 bits 1 245 Modbus Address for slave port 41510 FlowControlMeter 16 bits 0 1 0 Flow Single Meter 1 Flow with Proportioning Y 41511 FlowControl 16 bits 0 2 0 Prop Only 1 Flow Only 2 Prop Flow Control 41514 FlowTolerance 16 bits 0 50 0 50 41515 FlowSetpoint 16 bits 0 1200 Manual Scaled F...

Страница 14: ...FFF Y 42045 TotalA6 32 bits 0 0xFFFF_FFFF Y 42047 TotalA7 32 bits 0 0xFFFF_FFFF Y 42049 TotalA8 32 bits 0 0xFFFF_FFFF Y 42051 TotalA9 32 bits 0 0xFFFF_FFFF Y 42053 TotalA10 32 bits 0 0xFFFF_FFFF Y 42055 TotalA11 32 bits 0 0xFFFF_FFFF Y 42057 TotalA12 32 bits 0 0xFFFF_FFFF Y 42059 TotalA13 32 bits 0 0xFFFF_FFFF Y 42061 TotalA14 32 bits 0 0xFFFF_FFFF Y 42063 TotalA15 32 bits 0 0xFFFF_FFFF Y 42065 To...

Страница 15: ...TotalA57 32 bits 0 0xFFFF_FFFF Y 42149 TotalA58 32 bits 0 0xFFFF_FFFF Y 42151 TotalA59 32 bits 0 0xFFFF_FFFF Y 42153 TotalA60 32 bits 0 0xFFFF_FFFF Total for Recipe 60 A material CCs Y 42155 TotalB0 32 bits 0 0xFFFF_FFFF Total for Recipe 0 B material CCs Y 42157 TotalB1 32 bits 0 0xFFFF_FFFF Y 42159 TotalB2 32 bits 0 0xFFFF_FFFF Y 42161 TotalB3 32 bits 0 0xFFFF_FFFF Y 42163 TotalB4 32 bits 0 0xFFF...

Страница 16: ...FFF Y 42235 TotalB40 32 bits 0 0xFFFF_FFFF Y 42237 TotalB41 32 bits 0 0xFFFF_FFFF Y 42239 TotalB42 32 bits 0 0xFFFF_FFFF Y 42241 TotalB43 32 bits 0 0xFFFF_FFFF Y 42243 TotalB44 32 bits 0 0xFFFF_FFFF Y 42245 TotalB45 32 bits 0 0xFFFF_FFFF Y 42247 TotalB46 32 bits 0 0xFFFF_FFFF Y 42249 TotalB47 32 bits 0 0xFFFF_FFFF Y 42251 TotalB48 32 bits 0 0xFFFF_FFFF Y 42253 TotalB49 32 bits 0 0xFFFF_FFFF Y 4225...

Страница 17: ...0_0000_0000_0010 Purge Start Set bit active 1 to initiate or start purging material mix must be inac tive 2 0000_0000_0000_0100 Color Change Start Set bit active 1 to initiate or start color change both mix and purge must be inactive 8 3 0000_000X_XXXX_X000 Recipe Bits 6 Set bit to select recipe See next sheet 9 0000_0010_0000_0000 Gun Trigger Set bit active 1 when gun is triggered Used by softwar...

Страница 18: ... 0 0 1 0 1 0 10 1 0 1 0 1 1 43 0 0 1 0 1 1 11 1 0 1 1 0 0 44 0 0 1 1 0 0 12 1 0 1 1 0 1 45 0 0 1 1 0 1 13 1 0 1 1 1 0 46 0 0 1 1 1 0 14 1 0 1 1 1 1 47 0 0 1 1 1 1 15 1 1 0 0 0 0 48 0 1 0 0 0 0 16 1 1 0 0 0 1 49 0 1 0 0 0 1 17 1 1 0 0 1 0 50 0 1 0 0 1 0 18 1 1 0 0 1 1 51 0 1 0 0 1 1 19 1 1 0 1 0 0 52 0 1 0 1 0 0 20 1 1 0 1 0 1 53 0 1 0 1 0 1 21 1 1 0 1 1 0 54 0 1 0 1 1 0 22 1 1 0 1 1 1 55 0 1 0 1 1...

Страница 19: ...r MIX_ACTIVE off Wait for system to complete request wait 100ms Set recipe bits Set the recipe bits for the next color wait 100ms Set Color Change Start Set color change bit to initiate start of color change wait 100ms Check for Purge CC Active Check if status output indicate the change wait 100ms Wait for Mix Ready active Wait for completion of the color change ...

Страница 20: ... 1 5 Install bulkhead connector 2 in bottom of enclosure 9 9 Ref No Part No Description Qty 1 120090 CONVERTER modbus TCP 1 2 198165 KIT accessory RJ45 Jack Bulkhead 1 3 117162 CABLE modular RJ45 3ft 1 5 15G635 HARNESS wire modbus TCP 1 9 n a HOLDER wire tie 2 ...

Страница 21: ... POWER SUPPLY 120369 1 2 3 GRND TERM MODBUS TCP CONVERTER 120090 J11 249306 RS485 24 VDC BLUE COM BLUE WHITE A BLACK A BLACK B NATURAL B NATURAL SHIELD GRND SHIELD GRND COM BLUE WHITE 24 VDC BLUE COMMUNICATION CABLE 117162 RJ45 BULKHEAD 198165 GRND GREEN YELLOW GRND GREEN YELLOW ...

Страница 22: ...rkmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as...

Отзывы: