Technical Data
US
Metric
Maximum Pressures:
Maximum inlet air pressure I/P transducer
130 psig
10.3 bar
Maximum fluid working pressure
289813 G3000 Meter
4000 psi
28 MPa, 276 bar
24C375 Fluid Regulator
100 psi
0.7 MPa, 7 bar
Maximum fluid inlet pressure
24C375 Fluid Regulator
300 psi
2.1 MPa, 21 bar
Power In Requirements:
Voltage:
90–264 VAC
Frequency:
50-60 Hz
Phase:
1
Amps:
1.25A maximum
Power Out Requirements:
Power Supply 16V680
15 VDC, 1.2 A maximum
Power Supply 16M167
15 VDC, 160mA maximum
Environmental
Operating Temperature
32°-122°F
0°-50°C
Storage Temperature
–22°-140°F
–30°-60°C
Humidity
0 to 95 percent, non-condensing
Display housing is solvent resistant.
Wetted Parts
Meter
See G3000 meter manual (308778) or Coriolis
meter manual (313599)
Fluid Regulator
See Fluid Regulator Manual (3A0427)
Fittings
Stainless Steel
Weight
ProControl 1KE
1.5 lb
0.68 kg
Mounting Bracket
1 lb
0.45 kg
Power Supply 16M167
9 lb
4.1 kg
Fluid Plate (fully populated)
10.5 lb
4.76 kg
3A2614H
53
Содержание ProControl 1KE
Страница 16: ...Installation Typical Installation Non Hazardous Location Hazardous Location 16 3A2614H ...
Страница 34: ...Parts Parts Kits for Hazardous Location 24L085 24P593 24P595 24L087 24P597 24L089 24L091 34 3A2614H ...
Страница 36: ...Parts Kits for Non Hazardous Location 24L084 24L086 24L088 24L090 24P592 24P594 24P596 36 3A2614H ...
Страница 38: ...Parts Fluid and Air Control Parts 38 3A2614H ...
Страница 52: ...Notes Notes 52 3A2614H ...