PARAMETERS
Setup
Screen
Display
(A1)
Value
Description
Display (A3) Values
Display
(A4)
Value
5
P05
Reserved
This selection is not implemented in this version of
the controller.
0: Reserved
rES1
6
P06
CAN Purpose ID
Use to set the purpose ID for CAN communications.
0-31
0 (default)
variable
7
P07
Log level
Display A2: LoG
Use to designate how much information is logged
in the system.
0–5
2 (default)
LoG
CONFIGURATION
Setup
Screen
Display (A1)
Value
Description
Display (A2) Values
8
C0
Arc detection rate of change set point averaging
interval Δt [sec]
Use to set the time interval that the controller will use to
calculate the spraying current / voltage rate of change.
0.01 – 1.00 by 0.01
0.01 (default)
9
C1
Arc detection blanking time setpoint [sec]
Use to set the amount of time after turning on the high
voltage during which arc protection is suppressed.
0.0 – 2.0 by 0.1
0.5 (default)
10
C2
Discharge timer setpoint [sec]
Use to set the time needed to fully discharge after
turning off the high voltage. After the timer expires,
the controller pulls the Electrostatic Discharge Output
high.
0.0 – 60.0 by 0.1
0.0 (soventborne default)
30.0 (waterborne default)
11
C3
Voltage Change Interval [sec]
Use to set the interval of transition time between
high voltage set points. This setting may be required
depending on arc detection settings.
0.0 – 5.0 by 0.1
0.0 (default)
34
333266D
Содержание Pro Xpc 24Y307
Страница 47: ...Screen Map RUN SETUP SCREENS 0 7 Parameters SETUP SCREENS 8 11 Configurations T1 T2 T1 T2 T1 T2 333266D 47 ...
Страница 56: ...Dimensions Dimensions Controller 56 333266D ...
Страница 57: ...Dimensions Flush Mount 6 26 in 15 9 cm 5 71 in 15 0 cm 7 65 in 19 4 cm 3 30 in 8 4 cm M6 X 1 mm 333266D 57 ...
Страница 58: ...Dimensions Wall Mount Bracket 17H288 58 333266D ...