![Graco Pro Xpc 24Y307 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/graco/pro-xpc-24y307/pro-xpc-24y307_instructions-manual_2251230019.webp)
Signals
Note on Digital Inputs and Outputs: A “0” is used to indicate that GND or no signal is present. A “1” is used to
indicate that a 24VDC signal is present.
Pin
Type
Description
1
Digital Input
2
Digital Input
Preset Select 1 and Preset Select 2
Use to specify the Preset selection in REMOTE operation:
Pin #2=0, Pin #1=0: Preset 0 (P000)
Pin #2=0, Pin #1=1: Preset 1 (P001)
Pin #2=1, Pin #1=0: Preset 2 (P002)
Pin #2=1, Pin #1=1: Preset 3 (P003)
In REMOTE mode, the values for Preset 0 are based on the analog signals received
on the discrete I/O interface. These values will overwrite any existing values in
Preset 0.
Presets 1–3 must be entered locally, using the keypad, prior to placing the controller
in REMOTE mode. It is not possible to change the settings of these Presets remotely.
3
Digital Input
Error Reset
Use to allow error codes to be acknowledged remotely. Acknowledging an error code
does not correct the condition that created the error.
0➔1 transition: Reset all reported errors
NOTE: Additional errors will be logged, regardless of the state of the Error reset,
but to perform additional error resets will require the signal to once again transition
from 0 to 1.
4
Digital Input
REMOTE Enable/Disable
Use to enable or disable REMOTE operation. Enabling REMOTE operation locks
out local control and allows the controller to use the discrete I/O interface. When
enabled, the
icon on the display is lit.
0: Local control
1: REMOTE control
5
Digital Input
Electrostatic Enable
Use to enable or disable electrostatics output.
0: Turn off electrostatics.
1: Enable electrostatics. Other conditions, like interlocks, apply.
333266D
19
Содержание Pro Xpc 24Y307
Страница 47: ...Screen Map RUN SETUP SCREENS 0 7 Parameters SETUP SCREENS 8 11 Configurations T1 T2 T1 T2 T1 T2 333266D 47 ...
Страница 56: ...Dimensions Dimensions Controller 56 333266D ...
Страница 57: ...Dimensions Flush Mount 6 26 in 15 9 cm 5 71 in 15 0 cm 7 65 in 19 4 cm 3 30 in 8 4 cm M6 X 1 mm 333266D 57 ...
Страница 58: ...Dimensions Wall Mount Bracket 17H288 58 333266D ...