308496 47
Service
Part No. 238147 Fluid Regulator
Conversion Kit Installation
To add a fluid regulator to part no. 237603 and 236824
PRO 5500wb spray guns, follow this procedure:
1.
Prepare the gun for service as instructed on
page 35.
2.
Remove the barrel as instructed on page 41.
3.
Remove the fluid fitting (17) and o-rings (18, 22)
from the gun barrel. Refer to page 50.
4.
Make sure the o-ring (A) is in place on the regula-
tor outlet fitting (B). See Fig. 43.
5.
Screw the regulator outlet fitting (B) into the gun
barrel (C), and tighten the fitting securely.
6.
Apply high strength (green) Loctite
or equivalent.
to the adapter (88) threads, and install the adapter
into the gun body (D).
7.
Install the tube fitting (89) into the adapter (88).
8.
Install the barrel on the gun body as instructed on
page 44.
9.
Install the air tubing (90) between the regulator
elbow fitting (E) and the tube fitting (89). Cut the
tubing to the length needed.
10. Install the gun onto the manifold as instructed on
page 44.
NOTE: Use the parts drawing and list on pages 52 and
53 to order replacement parts for your gun after adding
the fluid regulator.
Conversion Kit Parts List
Includes items 2, 17, 88, 89, and 90
Ref.
No.
Part No.
Description
Qty.
2**
190905
SHROUD
1
17
238039
FLUID REGULATOR
1
88
190899
ADAPTER
1
89
111328
TUBE FITTING
1
90
054730
AIR TUBING; 5/32 O.D.
** Order the warning label 290069, at no cost, when order-
ing the shroud. Affix the label to the shroud.
1 ft. (305 mm) of tubing included with kit. To replace tub-
ing, order the length needed.
05494
17
90
89
88
2
A
Fig. 43
B
C
D
E
Содержание PRO 5500wb
Страница 49: ...308496 49 Notes ...
Страница 59: ...308496 59 Notes ...