308496 11
Installation
Install the Air Line Accessories
1.
Install an air line filter and an air and water separa-
tor on the main air supply line to ensure a dry,
clean air supply to the gun. Dirt and moisture can
ruin the appearance of your finished workpiece
and can cause the gun to malfunction.
2.
Install a bleed-type air shutoff valve (Q) on the
main air supply line to shut off all the air to the gun.
3.
Install a bleed-type air regulator (M) on each of the
gun air supply lines to control the air pressure to
the gun. See Fig. 2, page 10.
4.
Install a bleed-type air shutoff valve (L) on the fan
(C) and atomization (D) air lines to shut off the fan
and atomization air to the gun.
WARNING
PRESSURIZED EQUIPMENT HAZARD
Trapped air can cause the gun to spray
unexpectedly, which could result in a
serious injury, including splashing in the
eyes or on the skin. The bleed-type air shutoff
valve is required on the fan and atomization air
lines so trapped air will be relieved between the
valve and the gun after the valves are closed.
5.
Install a check valve (S) in the pilot air line (R) to
prevent fluid from backing up into the air controls.
Install the Gun and Mounting Bracket
CAUTION
To avoid electrical breakdown damage to the fluid
regulator and other gun components, do not have
any grounded objects within the minimum clearance
zone shown in Fig. 4 during gun operation.
Fig. 4
05937
A = 2 in. (51 mm)
= 4 in. (102 mm)
B
A
A
A
B
1.
Loosen the two square head bolts (103), and slide
the mounting bracket onto a 0.50 inch (12.7 mm)
mounting rod. See Fig. 5.
2.
Position the gun, and tighten the two bolts (103)
securely.
04301
Fig. 5
2.775 in.
(70.5 mm)
9.32 in.
(236.7 mm)
0.50 in.
(12.7 mm)
rod
103
103
NOTE: For added positioning reliability, the mounting
bracket (DD) has an 1/8 inch (3.2 mm) slot where a
locating pin (BB–not included) can be inserted through
the mounting rod (CC). See Fig. 6.
Fig. 6
03460
BB
CC
DD