Warnings 

4

309403R

SKIN INJECTION HAZARD 

Spray from the applicator, hose leaks, or ruptured components can inject fluid into your body and cause 
extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can 
also cause serious injury.

Fluid injected into the skin might look like just a cut, but it is a serious injury. 

Get immediate surgi-

cal treatment.

Do not point the applicator at anyone or at any part of the body.

Do not put hand or fingers over the front of the applicator.

Do not stop or deflect fluid leaks with your hand, body, glove, or rag.

follow the Pressure Relief Procedure whenever you are instructed to: relieve pressure; stop dispens-
ing; clean, check, or service the equipment; or install or clean a nozzle.

Tighten all the fluid connections before operating the equipment.

Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately. 
Permanently coupled hoses cannot be repaired; replace the entire hose.

Always wear eye protection and protective clothing when installing, operating, or servicing this dis-
pensing equipment.

Do not remove or modify any part of the applicator; this can cause a malfunction and result in seri-
ous bodily injury.

Use extreme caution when cleaning or changing nozzles. If the nozzle clogs while applying material, 
Always follow the Pressure Relief Procedure, then remove the nozzle to clean it.

Never wipe off build-up around the nozzle or inlet cap until pressure is fully relieved.

FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD

Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and 
result in fire or explosion and serious injury.

Ground the equipment and the object being dispensed. See Grounding.

Ground the equipment and the object being sprayed, and all other electrically conductive objects in 
the dispense area. Proper grounding dissipates static electricity generated in the equipment. See 
Grounding.

Do not use this equipment with flammable liquids.

Keep the dispense area free of debris, including solvent, rags, and gasoline.

If there is any static sparking or you feel an electric shock while using the equipment, stop 
dispensing immediately. Do not use the equipment until you have identified and corrected the 
problem.

Be sure all electrical work is performed by a qualified electrician only.

Have any checks, installation, or service to electrical equipment performed by a qualified electrician 
only.

Be sure all electrical equipment is installed and operated in compliance with applicable codes.

Be sure power is disconnected when servicing and repairing equipment.

Before operating the equipment, extinguish all open flames or pilot lights in the dispense area.

Do not smoke in the dispensing area.

Keep liquids away from the electrical components.

Disconnect electrical power at the main switch before servicing the equipment.

WARNING

Содержание PrecisionSwirl 243402

Страница 1: ...cations For professional use only Parts 243402 243403 289261 289262 and 26B185 3500 psi 24 1 MPa 241 bar Maximum Fluid Working Pressure Important Safety Instructions Read all warnings and instructions...

Страница 2: ...act Version 289261 289262 and 26B185 24 Technical Data 25 California Proposition 65 25 Graco Standard Warranty 26 Graco Information 26 Models Tool Mounted Dispensers Cable Assemblies Version Part Seri...

Страница 3: ...amaged parts immediately Do not exceed the maximum fluid working pressure of 3500 psi 241 bar 24 1 MPa to the dispenser or manifold Never exceed the recommended working pressure or the maximum air inl...

Страница 4: ...essure Relief Procedure then remove the nozzle to clean it Never wipe off build up around the nozzle or inlet cap until pressure is fully relieved FIRE EXPLOSION AND ELECTRIC SHOCK HAZARD Improper gro...

Страница 5: ...oid the buildup of vapors from the fluid being dispensed Know the specific hazards of the fluid you are using Store hazardous fluid in an approved container Dispose of hazardous fluid according to all...

Страница 6: ...Dispense Valve typical 3 4 16 37 SAE Swivel Union Match robot arm sup port with hole pattern matching orbiter both sides M5 x 0 8 Screws both sides 0 531in 0 519 in 0 800 in 0 150 in Dowel Pin Holes 0...

Страница 7: ...the control box PCF PrecisionSwirl 16K601 16K610 or Expan sion Swirl Enclosure 16M350 16M351 Use the receptacle located on the right side of the enclo sure 2 Connect the orbital dispenser cable 55 ft...

Страница 8: ...ts for a basic dispensing system Your sys tem may include other equipment or objects that must be grounded Check your local electrical code for detailed grounding instructions for your area and type o...

Страница 9: ...dispense valve fluid hose is completely clogged or if pressure has not been fully relieved after following the steps above very slowly loosen the 3 4 in 16 swivel union between the dispense valve and...

Страница 10: ...the distance from the nozzle to the sub strate The orbital dispenser motor must be turned on at least one second before applying a bead to ensure peak effi ciency Whether the PrecisionSwirl orbital d...

Страница 11: ...ral Guidelines for a Preventive Maintenance Schedule Service life is dependent upon on production load factors and material characteristics Preventive maintenance schedule for the bellows seal is depe...

Страница 12: ...to force tube free of orbiter cou pler assembly 24 11 Remove nozzle 15 from tube assembly 13 and remove tube assembly from motor assembly 6 and upper housing 3 12 If not using coupler repair kit 2462...

Страница 13: ...ush rod tool to press the bearing out of the coupler The push rod tool is the 4 in piece of bar stock included in Kit 241569 Discard the bearing 3 Use the gear puller and coupler removal tool included...

Страница 14: ...he bearing does not bottom out on the orbiter coupler Refer to FIG 5 for nominal press dimensions CAUTION Do not assemble the 0 028 in coupler assembly 241466 to the compact orbital dispensers 289261...

Страница 15: ...fitting to the inlet cap 8 Install the inlet cap swivel fitting assembly over the tube assembly 13 Screw the fitting onto the upper housing 3 until the tube assembly is firmly clamped against the uppe...

Страница 16: ...s Seal Replacement 1 Clean excess material from the bellows seal 140 and nozzle guard 80 2 Remove the nozzle guard 80 3 Remove the nozzle 15 4 Lift the bellows seal 140 and pull it over the threads on...

Страница 17: ...d 243403 1 Torque to 12 15 in lb 1 36 1 69 N m maximum See Table 4 on page 22 Torque to 17 20 ft lb 22 95 27 0 N m maximum Torque to 10 12 ft lb 27 0 33 75 N m maximum 1 2 3 4 2 3 4 3 4 1 2 12 13 6 15...

Страница 18: ...d 289262 Torque to 12 15 in lb 1 36 1 69 N m maximum See Table 4 on page 22 Torque to 17 20 ft lb 22 95 27 0 N m maximum Torque to 16 18 ft lb 21 6 24 3 N m maximum 1 2 3 4 2 3 4 3 4 1 2 12 13 6 150 5...

Страница 19: ...udes tube bearing 243402 only 1 24b 241466 COUPLER orbiter assy 0 028 offset includes tube bearing 243403 only 1 25 100020 WASHER lock 2 26 114135 SCREW mounting manifold 2 80 196038 GUARD nozzle 1 11...

Страница 20: ...Table 2 Motor Control Cables Part Number Length Description 617870 55 ft 16 8 m Motor cable assembly FIG 8 P N 617870 SOCKET PIN A B C D E H J K L M A B C D E H J K L M WHITE BROWN GREEN YELLOW GREY...

Страница 21: ...cables must be used in conjunction with the 55 ft motor cable Table 3 Motor Control Cables Part Number Length Description 233125 6 ft 1 8 m Motor cable assembly 233124 9 ft 2 7 m Motor cable assembly...

Страница 22: ...918613 0 043 in 1 092 mm 918614 0 047 in 1 194 mm 241813 0 051 in 1 295 mm 241814 0 055 in 1 397 mm Ref Part Description Qty 1 617825 TOOL push rod 1 2 617826 TOOL coupling support 1 3 617828 TOOL mo...

Страница 23: ...2 64 in 67 1 mm 5 00 in 127 0 mm 2 20 in 55 9 mm 9 04 in 229 6 mm 4 04 in 102 62 mm TI11232a TI11231a 1 54 in 39 12 mm 1 10 in 29 74 mm 0 28 in 7 11 mm 1 35 in 34 29 mm 1 21 in 30 73 mm 6 61 in 167 8...

Страница 24: ...26B185 FIG 12 1 125 in 1 1 in 0 150 in 3 81 mm 1 35 in 34 29 mm 7 035 in 178 68 mm 3 906 in 99 21 mm 5 38 in 136 65 mm 6 61 in 167 89 mm 1 2 in 30 48 mm 2 05 in 52 07 mm 3 25 in 82 55 mm 2 20 in 1 21...

Страница 25: ...WM voltage to motor less than 24V Motor torque 1 5 oz in Maximum motor speed 24 000 RPM Maximum operating pressure 3500 psi 24 1 MPa 241 bar Fluid inlet 3 4 16 37 JIC female swivel Nozzle attachment 1...

Страница 26: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRAN...

Отзывы: