Graco Monark Hydra-Spray 224-626 Скачать руководство пользователя страница 10

10 307-620

Operation/Maintenance

WARNING

To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 9.

8.

Relieve the pressure.

9.

Install the spray tip in the gun.

10. Control the pump speed and fluid pressure with

the air regulator (D).  Always use the lowest air
pressure necessary to get the desired results.
Higher pressure causes premature spray tip and
pump wear.

WARNING

COMPONENT RUPTURE HAZARD
To reduce the risk of overpressurizing
your system, which could cause     com-
ponent rupture and serious injury, 

never

exceed the specified maximum incoming air pres

-

sure to the pump (see Technical Data on page
15).

With the pump and lines primed, and with adequate air
pressure and volume supplied, the pump starts and
stops as the spray gun is opened and closed.  In a
circulating system, the pump runs continuously and
speeds up or slows down as supply increases or
decreases until the air supply is shut off.

Shutdown and Care of the Pump

WARNING

To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 9.

For overnight shutdown, relieve the pressure, and
always stop the pump at the bottom of the stroke to
prevent the fluid from drying on the exposed
displacement rod and damaging the throat packings.

Always flush the pump before the fluid dries on the
displacement rod.  See Flushing the Pump.

Flushing the Pump

FIRE AND EXPLOSION HAZARD
Before flushing, read the section FIRE
AND EXPLOSION HAZARD
 on page
4. Be sure the entire system and flush-
ing pails are properly grounded. Refer to
Grounding on page 5.

WARNING

Flush with a fluid that is compatible with the fluid you
are pumping and with the wetted parts in your system.
Check with your fluid manufacturer or supplier for
recommended flushing fluids and flushing frequency.
Always flush the pump before fluid dries on the
displacement rod.

Never leave water or water-base fluid in the pump
overnight.  If you are pumping water-base fluid,
flush with water first, then with a rust inhibitor such
as mineral spirits.  Relieve the pressure, but leave
the rust inhibitor in the pump to protect the parts
from corrosion. 

CAUTION

WARNING

To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 9.

1.

Relieve the pressure.

2.

Remove the spray tip from the gun.

3.

Hold a metal part of the gun firmly to the side of a
grounded 

metal pail.

4.

Start the pump. Always use the lowest possible
fluid pressure when flushing.

5.

Trigger the gun.

6.

Flush the system until clear solvent flows from the
gun.

7.

Relieve the pressure.

Содержание Monark Hydra-Spray 224-626

Страница 1: ...D portable caster cart with severe duty displacement pump hose and gun Model 224 626 Series A portable universal cart with severe duty displacement pump Model 231 159 portable universal cart with sev...

Страница 2: ...ion manuals tags and labels before operating the equipment D Use the equipment only for its intended purpose If you are not sure contact your Graco distribu tor D Do not alter or modify this equipment...

Страница 3: ...ck the gun trigger safety when you stop spraying Follow the Pressure Relief Procedure on page 9 if the spray tip clogs and before cleaning checking or servicing the equipment Tighten all fluid connect...

Страница 4: ...m solvents or the fluid being sprayed Keep the spray area free of debris including solvent rags and gasoline Electrically disconnect all equipment in the spray area Extinguish all open flames or pilot...

Страница 5: ...her end of the wire to a true earth ground For a ground wire and clamp order Part No 237 569 W Y X Z Fig 1 Air and fluid hoses Use only grounded hoses with 500 ft 150 m maximum combined hose length to...

Страница 6: ...ular needs KEY A Main air line B Bleed type master air valve for accessories C Air line filter D Air regulator E Bleed type master air valve for pump F Pump G Fluid filter H Fluid drain valve J Fluid...

Страница 7: ...and bleed valve E to provide automatic air motor lubrication Bleed type master air valve E Install downstream from the air regulator D and in a place that is easily accessible from the pump to relieve...

Страница 8: ...acket 3 Apply thread sealant and screw the nipple 129 into the outlet of the fluid filter 101 Install the long nipple 102 and filter 101 at the pump fluid outlet 4 Connect the gun swivel 128 and fluid...

Страница 9: ...TE Flush the pump before first use The pump is tested with lightweight oil which is left in to protect the pump parts If the fluid you are using may be contaminated by the oil flush the pump out with...

Страница 10: ...f the stroke to prevent the fluid from drying on the exposed displacement rod and damaging the throat packings Always flush the pump before the fluid dries on the displacement rod See Flushing the Pum...

Страница 11: ...11 307 620 Notes...

Страница 12: ...mbe 3 5 ft 1 m long w spring guard 1 14 206 831 CHECK VALVE see manual 306 861 1 15 206 994 THROAT SEAL LIQUID 8 oz 0 23 liters not shown 1 Ref No Part No Description Qty 16 218 029 FLUID FILTER see m...

Страница 13: ...d 1 8 npt 3 113 207 365 BRACKET wall mount see manual 306 783 1 114 100 349 ELBOW inlet 90 3 4 npt fbe 1 115 235 462 SPRAY GUN airless see manual 308 236 1 116 SPRAY TIP customer s choice 1 117 214 69...

Страница 14: ...162 376 MANIFOLD air 1 2 npt m x 1 2 npt f swivel three 1 8 npt f tapped holes 1 221 165 767 SUCTION TUBE 3 4 npt 18 in 457 mm long 1 222 162 453 NIPPLE 1 4 npt x 1 4 npsm 1 228 206 197 AIR REGULATOR...

Страница 15: ...on aluminum nylon carbon steel fittings zinc plated carbon steel Sound levels were measured at 100 psi 0 7 MPa 7 bar air at 60 cycles per minute per ISO 3744 1981 In most cases the hose is the limitin...

Страница 16: ...forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or c...

Отзывы: