background image

22

TECHNICAL AND PERFORMANCE DATA (222–783 PRESIDENT)

Maximum fluid working pressure

320 bar (4600 psi)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Maximum air input pressure

7 bar (100 psi)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Pump cycles per 3.8 liters (1 gal.)

100

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Maximum recommended pump speed for continuous operation

40 cycles per min

. . . . . . . . . 

Maximum recommended pump speed

60 cycles per min

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Maximum flow

2.28 liters/min (0.6 gpm) at 60 cycles/min

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Air motor effective diameter

108 mm (4.25”)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Stroke length

102 mm (4”)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Displacement pump effective area

2 cm

@

 (0.310 in.

@

)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Maximum pump operating temperature

65.5

_

C (150

_

F)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Air inlet size

1/2 npt(f)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Fluid outlet size

1/2 npt(m)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Weight

21.8 kg (48 lb)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Wetted  parts

Carbon Steel; E52100, 41L40, and 4140 Alloy Steel; Ductile Iron;

. . . . . . . . . . . 

AISI 304, 316, and 17–4 PH grades of Stainless Steel;

Chrome, Zinc, and Nickel Plating; 

r

; Glass–Filled 

r

; Delrin

r

;

Ultra–High Molecular Weight Polyethylene

 and Delrin

r

0

500

1000

1500

2000

2500

3000

3500

4000

4500

5000

0.0

0.2

0.4

0.6

0.8

FLUID FLOW (TEST FLUID: 1900 CENTIPOISE OIL)

gpm

liters/min

To find Fluid Outlet Pressure

 (bar/psi) at a specific fluid flow (lpm/gpm)

and operating air pressure (bar/psi):

1. Locate desired flow along bottom of chart.

2. Follow vertical line up to intersection with selected fluid outlet pres-

sure curve (black). Follow left to scale to read fluid outlet pressure.

To find Pump Air Consumption

 (m

#

/min or scfm) at a specific fluid flow

(lpm/gpm) and air pressure (bar/psi):

1. Locate desired flow along bottom of chart.

2. Read vertical line up to intersection with selected air consumption

curve (gray). Follow right to scale to read air consumption.

0.76

35

cycles/min

40

scfm

m

#

/

min

6

30

42

1.17

6

0.840

0.168

psi

bar

7 bar (100 psi)

air pressure

4.9 bar (70 psi)

air pressure

7 bar (100 psi)

air pressure

4.9 bar (70 psi)

air pressure

KEY:

Fluid Outlet Pressure – Black Curves

Air Consumption – Gray Curves

NOTE:

Maximum recommended pump speed for

continuous operation: 40 cpm

Maximum recommended pump speed

(to shaded area): 60 cpm

60

70

105

140

210

175

245

80

12

0.336

18

0.504

24

0.672

315

36

1.00

8

280

1.52

2.28

3.04

48

1.34

4

2.8 bar (40 psi)

air pressure

2.8 bar (40 psi)

air pressure

20

350

PTFE

PTFE

PTFE

Содержание Metric CHECK-MATE 200

Страница 1: ...OX 1441 MINNEAPOLIS MN 55440 1441 COPYRIGHT 1991 GRACO INC TABLE OF CONTENTS Warnings 2 3 Terms 3 Typical Installation 4 Installation 5 Operation Maintenance 6 7 Service Troubleshooting Chart 8 Requir...

Страница 2: ...Whenever you stop spraying dispensing even for a moment always set the spray gun dispensing valve safety latch in the closed or safe posi tion making the gun valve inoperative Failure to set the safe...

Страница 3: ...is created by the high velocity flow of fluid through the pump and hose If every part of the spray dispensing equipment is not properly grounded sparking may occur and the system may become hazardous...

Страница 4: ...Air Line Lubricator J Bleed Type Master Air Valve required for pump K Air Regulator L Air Line Filter M Bleed Type Master Air Valve for accessories N Fluid Drain Valve required P Fluid Pressure Regula...

Страница 5: ...gallon ram Refer to Accessories on page 19 and the separate manuals included with the kits for further information Air Line Accessories Install the following accessories in the order shown in the Typ...

Страница 6: ...pump starts Moving parts can pinch or amputate your fingers or other body parts When the pump is operating the priming piston 23 located at the pump intake and the air motor piston located behind the...

Страница 7: ...he exposed displacement rod and damaging the throat packings Always flush the pump before the fluid dries on the dis placement rod Never leave water or water based fluid in the pump overnight First fl...

Страница 8: ...mp Replace packings To determine if the fluid hose or gun is obstructed follow the Pressure Relief Procedure Warning below Disconnect the fluid hose and place a container at the pump fluid outlet to c...

Страница 9: ...3 Remove the coupling collars 105 Take care not to lose or drop them See Fig 3 4 Hold the tie rod flats with an 11 mm wrench to keep them from turning Use the wrench 1 13 provided with the pump or a 1...

Страница 10: ...king nut 2 throat packings 3 5 and glands 4 6 from the outlet housing 9 DO NOT remove the fluid outlet nipple 7 and o ring 8 from the outlet housing unless they need replace ment 10 Unscrew the bleede...

Страница 11: ...QUE TO 21 27 N m 15 20 ft lb 21 TORQUE TO 34 41 N m 25 30 ft lb 4 5 6 3 LIPS OF V PACKINGS MUST FACE DOWN THROAT PACKING DETAIL 7 REMOVE ONLY IF DAMAGED TORQUE TO 70 75 N m 51 55 ft lb 11 TORQUE TO 17...

Страница 12: ...ad lubricant to the bottom threads of the cylinder 11 Be sure the o ring 10 is in place on the cylinder Guide the intake valve housing 16 up onto the priming piston rod 21 Screw the valve housing onto...

Страница 13: ...UE TO 170 185 N m 125 135 ft lb 15 TORQUE TO 21 27 N m 15 20 ft lb 21 TORQUE TO 34 41 N m 25 30 ft lb 4 5 6 3 LIPS OF V PACKINGS MUST FACE DOWN THROAT PACKING DETAIL 7 REMOVE ONLY IF DAMAGED TORQUE TO...

Страница 14: ...O DESCRIPTION QTY 101 222 791 AIR MOTOR Monark See 307 043 for parts 1 102 184 076 ROD tie 295 mm 11 61 shoulder to shoulder 3 103 184 162 ROD adapter 1 104 184 100 NUT coupling 1 105 184 131 COLLAR c...

Страница 15: ...istributor 6 digit Part Number Qty Part Description 101 103 105 107 102 TORQUE TO 20 25 N m 15 18 ft lb 106 TORQUE TO 34 41 N m 25 30 ft lb 104 TORQUE TO 41 48 N m 30 35 ft lb REF PART NO NO DESCRIPTI...

Страница 16: ...TO 21 27 N m 15 20 ft lb 21 TORQUE TO 34 41 N m 25 30 ft lb 1 27 TORQUE TO 27 34 N m 20 25 ft lb 26 19 18 LARGE BEVEL MUST FACE DOWN 21 REF 24 23 FLAT SIDE MUST FACE UP 7 TORQUE TO 70 75 N m 51 55 ft...

Страница 17: ...y Consists of Ref No Qty 8 1 10 2 14 1 19 1 26 1 41 1 222 785 THROAT PACKING REPAIR KIT Must be purchased separately Consists of Ref No Qty 3 2 4 1 5 3 6 1 222 786 THROAT PACKING CONVERSION KIT To con...

Страница 18: ...LVE 215 362 12 bar 180 psi MAXIMUM WORKING PRESSURE Shuts off air supply to the pump if the pump accelerates beyond the pre adjusted setting due to an empty supply container interrupted fluid supply t...

Страница 19: ...raise pump from 19 liter 5 gallon pails Release of air pressure and weight of the pump cause it to move downward Use with wiper plate 222 812 Also requires Cart Accessory Kit 224 376 Re fer to Instruc...

Страница 20: ...Outlet Pressure bar psi at a specific fluid flow lpm gpm and operating air pressure bar psi 1 Locate desired flow along bottom of chart 2 Follow vertical line up to intersection with selected fluid ou...

Страница 21: ...lpm gpm and air pressure bar psi 1 Locate desired flow along bottom of chart 2 Read vertical line up to intersection with selected air consumption curve gray Follow right to scale to read air consump...

Страница 22: ...E OIL gpm liters min To find Fluid Outlet Pressure bar psi at a specific fluid flow lpm gpm and operating air pressure bar psi 1 Locate desired flow along bottom of chart 2 Follow vertical line up to...

Страница 23: ...id flow lpm gpm and air pressure bar psi 1 Locate desired flow along bottom of chart 2 Read vertical line up to intersection with selected air consumption curve gray Follow right to scale to read air...

Страница 24: ...A B C D Model 222 782 1147 mm 365 mm 782 mm 328 mm 45 2 in 14 35 in 30 8 in 12 9 in 222 783 1207 mm 418 mm 789 mm 328 mm 47 5 in 16 45 in 31 0 in 12 9 in DIMENSIONAL DRAWING Model 222 783 Shown A B C...

Страница 25: ...22 782 MONARK PUMP 63 5 mm 2 50 22 2 mm 0 875 62 50 mm 2 461 38 5 mm 1 516 31 2 mm 1 230 54 1 mm 2 131 44 5 mm 1 750 7 1 mm 0 281 DIA 2 11 4 mm 0 449 DIA 3 63 5 mm 2 50 54 1 mm 2 130 31 25 mm 1 230 62...

Страница 26: ...26 NOTES...

Страница 27: ...27 NOTES...

Страница 28: ...ade at a reasonable charge which charges may include the costs of parts labor and transportation DISCLAIMERS AND LIMITATIONS THE TERMS OF THIS WARRANTY CONSTITUTE PURCHASER S SOLE AND EXCLUSIVE REMEDY...

Страница 29: ...109 and 113 Add Model 237 203 Monark Pump Items 101 106 108 109 110 and 113 are the same as for Model 222 782 Item 102 is 190 161 Tie Rod Item 103 is 237 252 Connecting Rod Items 104 and 105 are not u...

Отзывы: