DataTrak Operation
313255F
23
Replace DataTrak Battery or Fuse
Replace Battery
1.
Unscrew cable from the back of the reed switch
assembly. See F
IG
. 10.
2.
Remove the cable from the two cable clips.
3.
Remove DataTrak module from bracket. See F
IG
.
11. Take module and attached cable to a non-haz-
ardous location.
4.
Remove two screws on back of module to access
battery.
5.
Disconnect the used battery and replace with an
approved battery. See F
IG
. 12.
Replace Fuse
1.
Remove the screw, metal strap, and plastic holder.
2.
Pull the fuse away from the board.
3.
Replace with a new fuse.
The battery and fuse must be replaced in a
non-hazardous location.
Use only the following approved replacement batter-
ies. Use of an unapproved battery will void Graco’s
warranty and FM and Ex approvals.
•
Ultralife lithium # U9VL
•
Duracell alkaline # MN1604
•
Energizer alkaline # 522
•
Varta alkaline # 4922
Use only a Graco-approved replacement fuse. Order
Part 24C580.
F
IG
. 10. Disconnect DataTrak
F
IG
. 11. Remove DataTrak
ti11992a
ti11884a
F
IG
. 12. DataTrak Battery and Fuse Location
ti11994a
Battery
Fuse
Solenoid Cable
Connection
Sensor Cable
Connection