Troubleshooting
12
334625B
Resin (A) or Catalyst (B) fluid back
flows into solvent supply line
Solvent supply valves are not fully
closed or are leaking
Clean and inspect fluid valves,
repair or replace as needed.
Solvent check valves are leaking
Verify shut off valves are fully
closed
Solvent flows into A or B fluid port
and static mixer.
Solvent supply valves are not fully
closed or are leaking
Clean and inspect fluid valves,
repair or replace as needed.
Verify shut off valves are fully
closed
A or B fluid continues to flow into
the mix manifold after the manifold
handle is placed in the “stand by”
position
A or B shut off valves are worn or
damaged
Repair or replace inlet ball valve on
A and B material inlets