![Graco LineLazer IV 3900 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/graco/linelazer-iv-3900/linelazer-iv-3900_repair-parts-list-manual_2250945021.webp)
Displacement Pump
312195B
21
Displacement Pump
Removal
1.
Flush pump.
2.
Relieve pressure, page 6.
3.
. 15. Cycle pump piston rod (A) to lowest position.
4.
. 15. Remove suction tube (34) and hose (100).
5.
. 16. Use screwdriver: push retaining spring up
and push out pin (235).
6.
. 17. Loosen locknut by hitting firmly with a 20 oz
(maximum) hammer. Unscrew pump.
7.
See manual 310643 for pump repair instructions.
Installation
1.
. 18. Pull piston rod out 1.5 in. Screw in pump
until holes in bearing cross link and piston rod align.
2.
. 16. Push pin (235) into hole. Push retaining
spring into groove around connecting rod.
3.
. 19. Screw jam nut onto pump until nut stops. Screw
pump into bearing housing until stopped by jam nut.
Back off pump and jam nut to align pump outlet to back.
Hand tighten jam nut; then tap 1/8 - 1/4 turn with a 20 oz
hammer to approximately 75 +/- 5 ft-lb (102 N•m).
4.
. 20. Fill packing nut with Graco TSL until fluid
flows onto the top of seal.
F
IG
. 15
F
IG
. 16
F
IG
. 17
100
A
34
TI7672c
TI7675b
235
TI7673b
If pin works loose, parts could break off due to force of
pumping action. Parts could project through the air and
result in serious injury or property damage. Make sure
pin and retaining spring are properly installed.
CAUTION
If the pump locknut loosens during operation, the
threads of the bearing housing will be damaged.
Make sure locknut is properly tightened.
F
IG
. 18
F
IG
. 19
F
IG
. 20
1.5 in.
TI7676b
TI7673b
TI7677b