4
308352
Installation
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section
FIRE AND EXPLOSION
HAZARD
on page 3.
1.
Pump:
use a ground wire and clamp. See Fig. 1.
Remove the ground screw (Z) and insert through
eye of ring terminal at the end of ground wire (Y).
Fasten ground screw back onto pump and tighten
securely. Connect the other end of the wire to a
true earth ground. Order Part No. 222011 Ground
Wire and Clamp.
Fig. 1
TI1052
Y
Z
2.
Air and fluid hoses:
use only electrically conductive
hoses.
3.
Air compressor:
follow manufacturer’s recommen-
dations.
4.
Spray gun/dispense valve:
ground through connec-
tion to a properly grounded fluid hose and pump.
5.
Fluid supply container:
follow your local code.
6.
Object being sprayed:
follow your local code.
7.
All solvent pails used when flushing:
follow your
local code. Use only metal pails, which are con-
ductive, placed on a grounded surface. Do not
place the pail on a nonconductive surface, such as
paper or cardboard, which interrupts the grounding
continuity.
8.
To maintain grounding continuity when flushing or
relieving pressure
, always hold a metal part of the
gun/valve firmly to the side of a grounded
metal
pail, then trigger the gun/valve.