14. With the air cylinder (319) up, place the air cover
(320) onto the air cylinder (319). Make sure that
o-ring (318) is in place on the cover. Grease the
o-ring.
15. Align the air port hole on the air cover with the
front of the pump. The hole should align between
the fluid port fittings on the fluid cover (311).
16. Spin the tie rod screws (312), lock washer (304),
and plain washer (322) into the air cover (320).
Tighten in a cross pattern only until snug.
17. Lay the pump on its side to tighten the tie rod
screws (312) in a cross pattern. Torque to 160
in-lb (18 N•m).
18. Attach the air valve assembly (323-326) to the air
cover (320). Tighten so that the air fitting faces
to the left.
19. Grease the o-ring at the base of the linear sensor
(321). Insert the sensor (321) into the top of the
air cover (320). Screw until tight.
Figure 51 Align Covers with Weep Holes
Remove
Remove
Remove the
the
the Fluid
Fluid
Fluid Regulator
Regulator
Regulator
Remove the fluid regulator for service. Refer to
the fluid pressure regulator instruction manual for
information on how to service the regulator. See
.
1.
Follow the
Pressure Relief Procedure, page 30
.
2.
Follow the voltage discharge and ground
procedure. (
).
3.
Shut the ball valve (39).
4.
Disconnect the fluid line from the elbow fitting
(75).
5.
Disconnect the fluid hose from the tube
compression fitting (82).
6.
Disconnect the air line.
7.
Disconnect the jump wire from the bleed resistor
to the fluid regulator (21).
8.
Remove the six hex screws (20), lock washers
(22), and flat washers (19) that attach the fluid
regulator (21) to the enclosure (9).
9.
Remove the fluid regulator (21).
Install
Install
Install the
the
the Fluid
Fluid
Fluid Regulator
Regulator
Regulator
1.
Use the six hex screws (20), lock washers
(22), and flat washers (19) to reattach the fluid
regulator (21) to the enclosure (9).
2.
Connect the jump wire from the bleed
resistor to the fluid regulator (21). See
3.
Connect the air line.
See
Pneumatic Connections, page 109
4.
Connect the fluid hose to the tube compression
fitting (82).
5.
Connect the fluid line to the elbow fitting (75).
6.
Open the ball valve (39) (handle up).
104