Troubleshooting
310796F
11
1.
Relieve pressure, page 8. Stop pump at bottom of
its stroke before servicing.
2.
Faulty fluid manifold check valves (219) can mask
pump problems. Keep the check valves operating
properly.
3.
This chart is specific to the air motor and pump.
Refer to the other supplied manuals to troubleshoot
individual components.
This chart uses proportioner gauges to determine pump malfunctions. A 2 pump proportioner is shown for clarity.
Observe the gauge readings during the stroke direction indicated by the bold arrow, and immediately after closing the
manifold.
WARNING
Read warnings, page 6.
TROUBLE AREA:
Resin Pump Leakage
1.
Throat packing
2.
Piston packing
3.
Piston ball check
Resin
Pump
Falling
Rising
Hardener
Pump
Falling
Falling
Rising
Rising
TROUBLE AREA:
Hardener Pump Leakage
1.
Throat packing
2.
Piston packing
3.
Piston ball check
TROUBLE AREA:
Resin Pump Leakage
1.
Throat packing
2.
Intake ball check
TROUBLE AREA:
Hardener Pump Leakage
1.
Throat packing
2.
Intake ball check
Resin
Pump
Hardener
Pump
Falling
Rising
Resin
Pump
Hardener
Pump
Resin
Pump
Hardener
Pump
Содержание Hydra-Cat TI5556b