Start the mixer motor before opening the material
valves. Then close the valves before stopping the
motor.
When you stop dispensing for 10 minutes or longer,
stop the mixer motor to prevent heat build up caused by
friction. Do not allow the system to stand idle for more
than the mixed material pot life.
For the most consistent results, always fully open the
actuating lever when dispensing. If a dispensing valve is
used, you can leave the mixer material valves open until
you are ready to flush.
For automatic mixer motor lubrication, install an air line
lubricator ahead of the motor. For manual lubrication,
remove the plug in the air motor head and place 10 to 15
drops of oil into the motor each day. Use only
lightweight machine oil.
BE SURE AIR
MOTOR IS
LUBRICATED
PROPERLY
When you stop dispensing for a short time, close the
mixer material valves and open the solvent flush valve.
Leave the motor running. Point the material outlet into a
waste container, open the dispensing valve and flush
until the solvent is clean. Close the solvent valve, stop
the motor and open the dispensing valve to relieve
pressure.
For longer shutdowns, solvent flush as above, follow
the Pressure Relief Procedure on page 6, then discon-
nect the dispensing hose and equipment from the mix-
er. Unscrew the adapter
from the mixing chamber
and remove the mixing shaft (204). Soak and clean
parts with clean solvent and a stiff brush. Rinse and
blow dry with air. Clean all material off the mixer
chamber. Do not reassemble until you are ready to use
the mixer again.
Solvent may channel through viscous materials and
leave a coating of mixed material on the inner tube of
your hose. Be sure all material is thoroughly flushed
from the hose after each use.
Disassemble all other dispensing equipment, as
necessary, and clean thoroughly.