Installation

Mountings

CAUTION

The pump exhaust air may contain contaminants.
Ventilate to a remote area if contaminants could
affect your fluid supply.  See Air Exhaust Ventila-
tion
 on page 7.

D

Be sure the mounting can support the weight of the
pump, hoses, and accessories, as well as the
stress caused during operation.

D

For all mountings, be sure the pump is secured with
screws through the mounting feet (58).  See the
mounting feet in the Parts Drawing on page 22.

Air Line

WARNING

A bleed-type master air valve and a fluid drain
valve are required on your system.

The bleed-type master air valve relieves air
trapped between itself and the pump.  Trapped air
can cause the pump to cycle unexpectedly, which
could result in serious bodily injury, including
splashing in the eyes, injury from moving parts, or
contamination from hazardous fluids.

The fluid drain valve reduces the risk of serious
bodily injury, including splashing in the eyes or on
the skin, or contamination from hazardous fluids.
Install the fluid drain valve close to the pump’s
fluid outlet to relieve pressure in the hose if the
hose becomes plugged.

1.

Mount the air line accessories on the wall or on a
bracket.  Be sure the air line supplying the
accessories is grounded.

a.

The pump speed can be controlled in one of
two ways:  To control it on the air side, install
an air regulator.  To control it on the fluid side,
install a fluid valve near the outlet.

b.

Install a bleed-type master air valve
downstream from the air regulator, and use it
to relieve trapped air.  See the WARNING,
above.  Locate another bleed-type master air
valve upstream from all air line accessories,
and use it to isolate the accessories during
cleaning and repair.

c.

The air line filter removes harmful dirt and
moisture from the compressed air supply.

2.

Install a flexible air hose between the accessories
and the pump air inlet.  Screw the air line fitting
into the air inlet.

3.

Do not restrict the exhaust port.  Excessive
exhaust restriction can cause erratic pump
operation.

Fluid Lines

WARNING

Graco always recommends that you use grounded
fluid hoses to dissipate static electricity.  When
pumping non-conductive flammable fluids, groun-
ded fluid hoses are required.  See Fire and Explo-
sion Hazard
 on page 3.

Fluid Outlet Line

1.

Attach the fluid outlet hose to the fluid outlet flange
by using a 3-in. ANSI or DIN flanged hose or pipe.

2.

Install a fluid drain valve near the fluid outlet.  See
the WARNING in the Air Line section at left.

Fluid Suction Line

Attach the fluid suction hose to the pump fluid inlet
flange by using a 3-in. ANSI or DIN flanged fluid
suction hose or pipe.

D

If the inlet pressure to the pump is more than 25
percent of the outlet working pressure, the ball
check valves do not close fast enough, which
results in inefficient pump operation.

D

At inlet fluid pressures over 15 psi (100 kPa, 1.0
bar), diaphragm life is shortened.

D

The maximum suction lift is 8 ft (2.5 m) of water dry
or 28 ft (8.5 m) of water wet.  For suction lifts
between 8 ft (2.5 m) and 28 ft (8.5 m) of water, it is
necessary to install a foot valve, and it is necessary
to flood the suction to prime the pump.  The pump
may prime better if you reduce the inlet air pressure
until the pump is primed.

Содержание husky 3275

Страница 1: ...275 Pump See page 20 This model is certified US and Foreign Patents Pending 308639L ENG Important Safety Instructions Read all warning and instructions in this manual Save these instructions Refer to...

Страница 2: ...malfunction Use only genuine Graco parts and accessories D Check all equipment regularly and repair or replace worn or damaged parts immediately D Never exceed the recommended working pressure or the...

Страница 3: ...e a fire or explosion and serious injury and property damage D To reduce the risk of static sparking ground the pump and all other equipment used or located in the work area Check your local electrica...

Страница 4: ...first day of operation retorque the fasteners Although pump use varies a general guideline is to retorque fasteners every two months Grounding WARNING ELECTRIC SHOCK HAZARD This pump must be grounded...

Страница 5: ...er air valve for accessories F Air line filter G Fluid suction hose H Fluid supply J Ball valve for releasing collected moisture L Fluid outlet hose N Air inlet port R Fluid inlet port S Fluid outlet...

Страница 6: ...t to relieve trapped air See the WARNING above Locate another bleed type master air valve upstream from all air line accessories and use it to isolate the accessories during cleaning and repair c The...

Страница 7: ...FLUID HAZARD Be sure to read and follow the USING HAZARDOUS FLUIDS and FIRE OR EXPLOSION HAZARD warnings on page 3 before you operate this pump Be sure the system is properly ventilated for your type...

Страница 8: ...valve required for pump C Air regulator D Air Line quick disconnect E Master air valve for accessories F Air line filter J Ball valve for releasing collected moisture P Muffler T Grounded air exhaust...

Страница 9: ...to be sure they are tight Be sure to use a compatible liquid thread sealant on all male threads 3 Place the suction tube if used in the fluid to be pumped NOTE If the inlet pressure to the pump is mor...

Страница 10: ...ve the pressure before storing it for any length of time Use a compatible solvent WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressur...

Страница 11: ...essure and clear valve Pump operates erratically Suction line is clogged Inspect clear Sticky or leaking check valve balls 201 Clean or replace See page 14 Diaphragm 301 is ruptured Replace See pages...

Страница 12: ...out of the cavity Using a needle nose pliers pull the pilot block 16 straight up and out of the cavity 4 Pull the two actuator pistons 7 out of the bearings 8 Remove the u cup seals 9 from the pistons...

Страница 13: ...ctuator piston 7 so the lips of the packings face the narrow end of the piston 6 Grease the u cup seals 9 Insert the actuator pistons in the bearings 8 wide end first Leave the narrow end of each pist...

Страница 14: ...ues 2 Using a 15 mm socket wrench remove the bolts 54 holding the outlet manifold 50 to the fluid covers 51 3 Remove the seats 101 balls 201 and o rings 102 from the fluid covers 51 4 Remove the inlet...

Страница 15: ...r equivalent NOTE A Fluid Section Service Kit is available See the Repair Kit Matrix on page 21 to find the correct kit for your pump Parts included in the kit are marked with an asterisk in the Parts...

Страница 16: ...nd inspect for wear or damage Replace parts as needed Reassembly See Fig 8 1 Install each u cup seal 15 so the lips face away from the center of the pump Lubricate the u cup seals 2 Install a diaphrag...

Страница 17: ...DE must face center housing 2 Grease Torque to 100 to 120 ft lb 136 to 163 NSm 4 06327 06328 52 57 13 13 15 1 14 2 1 1 14 14 52 57 303 5 3 3 3 4 4 1 1 301 2 62 62 63 64 63 63 64 06329A 2 Used only in...

Страница 18: ...ove the air cover gaskets 10 Always replace the gaskets with new ones 7 Use a bearing puller to remove the diaphragm shaft bearings 13 piston actuator bearings 8 and push pin bearings 17 Do not remove...

Страница 19: ...Service Fig 9 2 1 Press fit bearings flush with surface of center housing 2 Detail of Bearings 06331 1 1 2 10 27 Torque to 19 to 21 ft lb 26 to 28 NSm 06330 8 17 H 18 1 1 2 through hole must be on bo...

Страница 20: ...atrix do not correspond to the reference numbers in the Parts Drawing and Parts Lists Diaphragm Pump Air Motor Fluid Section Seats Balls Diaphragms 232505 aluminum aluminum TPE acetal TPE D for all pu...

Страница 21: ...hird digit is always K The remaining three digits define the materials of construction Parts included in the kit are marked with an asterisk in the Parts Drawing on page 22 for example 201 For example...

Страница 22: ...54 24 60 1 54 51 50 Included in Air Valve Service Kit 238765 which may be purchased separately Kit includes 2 of 113554 Included in Fluid Section Service Kit See the Repair Kit Matrix on page 21 to fi...

Страница 23: ...grounding 1 24 104582 WASHER tab 1 27 114193 SCREW mach hex washer head 16 Included in Air Valve Service Kit 238765 which may be purchased separately Kit includes 2 of 113554 Included in Fluid Section...

Страница 24: ...page 21 to find the correct kit for your pump Technical Data Maximum fluid working pressure 120 psi 0 8 MPa 8 bar Air operating range 20 to 120 psi 0 14 to 0 8 MPa 1 4 to 8 bar Maximum air consumption...

Страница 25: ...e fasteners 1 Left Right Fluid Cover Torque bolts to 55 60 ft lb 75 81 NSm SIDE VIEW 12 11 1 2 3 4 5 6 7 9 8 10 2 Inlet Manifold Torque bolts to 55 60 ft lb 75 81 NSm BOTTOM VIEW 14 13 16 18 15 17 3 O...

Страница 26: ...D 24 5 in 622 5 mm 15 25 in 387 5 mm 0 185 in 5 mm Four 0 84 in 21 5 mm holes ANSI Eight 0 84 in 21 5 mm holes DIN Section A A A A Flanges are Flat Faced 3 4 npt f Air Inlet 1 npt f Air Exhaust muffle...

Страница 27: ...Outlet Pressure psi MPa bar at a specific fluid flow gpm lpm and operating air pressure psi MPa bar 1 Locate fluid flow rate along bottom of chart 2 Follow vertical line up to intersection with select...

Страница 28: ...4 MPa 1 4 bar air pressure 1 4 4 2 5 6 Test Conditions Pump tested in water with inlet submerged 7 0 9 8 AIR CONSUMPTION scfm cubic meters min 341 454 681 1022 2 8 8 4 C D To find Pump Air Consumption...

Страница 29: ...29 308639 Notes...

Страница 30: ...the date of sale Graco makes no warranty and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories equipment materials or components...

Отзывы: