Warnings

Warning Symbol

WARNING

This symbol alerts you to the possibility of serious
injury or death if you do not follow the instructions.

Caution Symbol

CAUTION

This symbol alerts you to the possibility of damage to
or destruction of equipment if you do not follow the
instructions.

EQUIPMENT MISUSE HAZARD

Any misuse of the equipment or accessories, such as overpressurizing, modifying parts, using
incompatible chemicals and fluids, or using worn or damaged parts, can cause them to rupture and
result in splashing in the eyes or on the skin, other serious injury, or fire, explosion or property dam-
age.

D

This equipment is for professional use only.  Observe all warnings.  Read and understand all
instruction manuals, warning labels, and tags before you operate the equipment.

D

Never alter or modify any part of this equipment; doing so could cause it to malfunction.  Use only
genuine Graco parts and accessories.

D

Check all equipment regularly and repair or replace worn or damaged parts immediately.

D

Never exceed the recommended working pressure or the maximum air inlet pressure stated on
your pump or in the Technical Data on page 24.

D

Do not exceed the maximum working pressure of the lowest rated component in your system.
This equipment has a 120 psi (0.8 MPa, 8 bar) maximum working pressure at 120 psi
(0.8 MPa, 8 bar) maximum incoming air pressure.

D

Be sure that all fluids and solvents used are chemically compatible with the wetted parts shown in
the Technical Data on page 24.  Always read the manufacturer’s literature before you use fluid
or solvent in the pump.

D

Never move or lift a pump under pressure.  If dropped, the fluid section may rupture.  Always
follow the Pressure Relief Procedure on page 9 before you move or lift the pump.

D

The pump weighs approximately 150 lb (68 kg) If it must be moved, use the lift ring, or have two
people lift the pump by grasping the outlet manifold.

WARNING

INSTRUCTIONS

Содержание husky 3275

Страница 1: ...275 Pump See page 20 This model is certified US and Foreign Patents Pending 308639L ENG Important Safety Instructions Read all warning and instructions in this manual Save these instructions Refer to...

Страница 2: ...malfunction Use only genuine Graco parts and accessories D Check all equipment regularly and repair or replace worn or damaged parts immediately D Never exceed the recommended working pressure or the...

Страница 3: ...e a fire or explosion and serious injury and property damage D To reduce the risk of static sparking ground the pump and all other equipment used or located in the work area Check your local electrica...

Страница 4: ...first day of operation retorque the fasteners Although pump use varies a general guideline is to retorque fasteners every two months Grounding WARNING ELECTRIC SHOCK HAZARD This pump must be grounded...

Страница 5: ...er air valve for accessories F Air line filter G Fluid suction hose H Fluid supply J Ball valve for releasing collected moisture L Fluid outlet hose N Air inlet port R Fluid inlet port S Fluid outlet...

Страница 6: ...t to relieve trapped air See the WARNING above Locate another bleed type master air valve upstream from all air line accessories and use it to isolate the accessories during cleaning and repair c The...

Страница 7: ...FLUID HAZARD Be sure to read and follow the USING HAZARDOUS FLUIDS and FIRE OR EXPLOSION HAZARD warnings on page 3 before you operate this pump Be sure the system is properly ventilated for your type...

Страница 8: ...valve required for pump C Air regulator D Air Line quick disconnect E Master air valve for accessories F Air line filter J Ball valve for releasing collected moisture P Muffler T Grounded air exhaust...

Страница 9: ...to be sure they are tight Be sure to use a compatible liquid thread sealant on all male threads 3 Place the suction tube if used in the fluid to be pumped NOTE If the inlet pressure to the pump is mor...

Страница 10: ...ve the pressure before storing it for any length of time Use a compatible solvent WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressur...

Страница 11: ...essure and clear valve Pump operates erratically Suction line is clogged Inspect clear Sticky or leaking check valve balls 201 Clean or replace See page 14 Diaphragm 301 is ruptured Replace See pages...

Страница 12: ...out of the cavity Using a needle nose pliers pull the pilot block 16 straight up and out of the cavity 4 Pull the two actuator pistons 7 out of the bearings 8 Remove the u cup seals 9 from the pistons...

Страница 13: ...ctuator piston 7 so the lips of the packings face the narrow end of the piston 6 Grease the u cup seals 9 Insert the actuator pistons in the bearings 8 wide end first Leave the narrow end of each pist...

Страница 14: ...ues 2 Using a 15 mm socket wrench remove the bolts 54 holding the outlet manifold 50 to the fluid covers 51 3 Remove the seats 101 balls 201 and o rings 102 from the fluid covers 51 4 Remove the inlet...

Страница 15: ...r equivalent NOTE A Fluid Section Service Kit is available See the Repair Kit Matrix on page 21 to find the correct kit for your pump Parts included in the kit are marked with an asterisk in the Parts...

Страница 16: ...nd inspect for wear or damage Replace parts as needed Reassembly See Fig 8 1 Install each u cup seal 15 so the lips face away from the center of the pump Lubricate the u cup seals 2 Install a diaphrag...

Страница 17: ...DE must face center housing 2 Grease Torque to 100 to 120 ft lb 136 to 163 NSm 4 06327 06328 52 57 13 13 15 1 14 2 1 1 14 14 52 57 303 5 3 3 3 4 4 1 1 301 2 62 62 63 64 63 63 64 06329A 2 Used only in...

Страница 18: ...ove the air cover gaskets 10 Always replace the gaskets with new ones 7 Use a bearing puller to remove the diaphragm shaft bearings 13 piston actuator bearings 8 and push pin bearings 17 Do not remove...

Страница 19: ...Service Fig 9 2 1 Press fit bearings flush with surface of center housing 2 Detail of Bearings 06331 1 1 2 10 27 Torque to 19 to 21 ft lb 26 to 28 NSm 06330 8 17 H 18 1 1 2 through hole must be on bo...

Страница 20: ...atrix do not correspond to the reference numbers in the Parts Drawing and Parts Lists Diaphragm Pump Air Motor Fluid Section Seats Balls Diaphragms 232505 aluminum aluminum TPE acetal TPE D for all pu...

Страница 21: ...hird digit is always K The remaining three digits define the materials of construction Parts included in the kit are marked with an asterisk in the Parts Drawing on page 22 for example 201 For example...

Страница 22: ...54 24 60 1 54 51 50 Included in Air Valve Service Kit 238765 which may be purchased separately Kit includes 2 of 113554 Included in Fluid Section Service Kit See the Repair Kit Matrix on page 21 to fi...

Страница 23: ...grounding 1 24 104582 WASHER tab 1 27 114193 SCREW mach hex washer head 16 Included in Air Valve Service Kit 238765 which may be purchased separately Kit includes 2 of 113554 Included in Fluid Section...

Страница 24: ...page 21 to find the correct kit for your pump Technical Data Maximum fluid working pressure 120 psi 0 8 MPa 8 bar Air operating range 20 to 120 psi 0 14 to 0 8 MPa 1 4 to 8 bar Maximum air consumption...

Страница 25: ...e fasteners 1 Left Right Fluid Cover Torque bolts to 55 60 ft lb 75 81 NSm SIDE VIEW 12 11 1 2 3 4 5 6 7 9 8 10 2 Inlet Manifold Torque bolts to 55 60 ft lb 75 81 NSm BOTTOM VIEW 14 13 16 18 15 17 3 O...

Страница 26: ...D 24 5 in 622 5 mm 15 25 in 387 5 mm 0 185 in 5 mm Four 0 84 in 21 5 mm holes ANSI Eight 0 84 in 21 5 mm holes DIN Section A A A A Flanges are Flat Faced 3 4 npt f Air Inlet 1 npt f Air Exhaust muffle...

Страница 27: ...Outlet Pressure psi MPa bar at a specific fluid flow gpm lpm and operating air pressure psi MPa bar 1 Locate fluid flow rate along bottom of chart 2 Follow vertical line up to intersection with select...

Страница 28: ...4 MPa 1 4 bar air pressure 1 4 4 2 5 6 Test Conditions Pump tested in water with inlet submerged 7 0 9 8 AIR CONSUMPTION scfm cubic meters min 341 454 681 1022 2 8 8 4 C D To find Pump Air Consumption...

Страница 29: ...29 308639 Notes...

Страница 30: ...the date of sale Graco makes no warranty and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories equipment materials or components...

Отзывы: