308553ZAE
9
Installation
BUNG-MOUNT TRANSFER INSTALLATION
F
IG
. 6
_____________________
WALL-MOUNT TRANSFER INSTALLATION
F
IG
. 7
_____________________
01444B
Y
J
C
N
L
F
H
B
E
M
A
D
01457B
Y
J
N
C
L
F
H
B
E
S
T
D
A
KEY
A
Husky 307 Pump
B
Bleed-Type Master Air Valve
(required for pump)
C
Air Supply Line
D
Air Line Quick Disconnect
E
Master Air Valve (for accessories)
F
Air Line Filter
H
Pump Air Regulator
J
Fluid Drain Valve (required)
L
Fluid Suction Line
M
Fluid Inlet Filter
N
Fluid Supply Hose
Y
Ground Wire (required; see page 5
for installation instructions)
KEY
A
Husky 307 Pump
B
Bleed-Type Master Air Valve
(required for pump)
C
Air Supply Line
D
Air Line Quick Disconnect
E
Master Air Valve (for accessories)
F
Air Line Filter
H
Pump Air Regulator
J
Fluid Drain Valve (required)
L
Fluid Suction Line
N
Fluid Supply Hose
S
Wall Bracket
T
Bung Adapter
Y
Ground Wire (required; see page 5
for installation instructions)
Tel: 866-777-6060
Fax: 866-777-6383
Springer Pumps, LLC
Website: www.springerpumps.com
Int'l: +001 267 404 2910