background image

Operation

Pressure Relief Procedure

The system remains pressurized until pressure is

manually relieved. To reduce the risk of serious
injury from pressurized fluid, accidental spray from
the gun, or splashing of any fluid, follow this proce-
dure whenever you

Are instructed to relieve pressure

Stop spraying

l

Check or service any system equipment

l

Install, clean, or change spray nozzles

1 .

Be sure the pump air regulator (6a) is still open.

Close the master air valve (A) to relieve pump air

pressure.

.

2 .

Close both air regulators 

3 .

Turn the 3-way valve 

(9) 

to 

Drain.

4 .

Trigger the spray gun into a waste pail to relieve
fluid pressure.

5 .

Turn off and unplug the heater (3).

II.

Flush the Pump Before First Use

Flush with a solvent compatible to your fluid. Consult
the fluid manufacturer’s literature for recommenda-
tions. See 

Flushing 

on page IO.

Priming the System

See Fig. 7.

Put the suction tube (15) in the prepared fluid.

KEY

A

Bleed-type master air valve

C

A i r   l i n e

3

fluid heater

6 a

Pump air regulator

6 b

Gun air regulator

9

3-way valve

1 3

Drain hose

44’

Fluid regulator

4 8

Filter drain valve

2 .

Hook the drain hose (13) on the waste pail.

3 .

Close the filter drain valve (48).

4 .

Turn the 

 valve 

(9) 

to 

Drain.

5 .

Open the fluid pressure regulator (44) (fully
clockwise).

6 .

Turn the needle valve (5) ail the way out

(counterclockwise)

7 .

Close the gun and pump air regulators 

 (full

counterclockwise).

8 .

Connect the air line (C) to the pump.

9 .

Open the master air valves (A).

10. Slowly raise the pump air regulator 

 pressure

to 20 to 30 psi (1.4 to 2.1 bar). The pump will cycle
quickly until is it primed. When it is primed, the
pump will stall against pressure. Now set the pump
air pressure to 40 psi (2.8 bar). When fluid flows
from the drain hose, turn the 3-way valve to 

Circu-

late.

11. Hold the gun against and aimed into a grounded

metal waste pail. Trigger the gun, and slowly open
the fluid regulator (44). The gun will emit air until
the fluid arrives. When fluid flows freely, release
the gun trigger.

.

Fig. 

7

a

308-448

Содержание HEATED AIR SPRAY PACKAGE 237410

Страница 1: ......

Страница 2: ...rough 17j listed below 17a Front Bracket Part No 191 902 Qty 1 17b Capscrew Part No 108 768 Qty 2 17c Flat Washer Part No 108 788 Qty 2 17d Keps Nut Part No 113 761 Qty 2 17e Warning Label Part No 290 331 Qty 1 17f Wheel Part No 106 062 Qty 2 17g Hub Part No 104 811 Qty 2 17h Retaining Ring Part No 101 242 Qty 2 17j Tube Plug Part No 112 853 Qty 2 100 021 36 Capscrew Change quantity to 4 100 015 3...

Страница 3: ...led hoses cannot be repaired l Handle and route hoses and tubes carefully Keep the hoses and tubes away from moving parts and hot surfaces Do not use the hoses to pull equipment Do not expose Grace hoses to tem peratures above 18Q F 82 C or below 40 F 40 C m FiRE AND EXPLOSION HAZARD Improper grounding poor air ventilation open flames or sparks can cause a hazardous condition and result in a fire ...

Страница 4: ...e fluids or solvents that are compatible with equipment wetted parts See the Technical Data section of all equipment manuals Read the fluid and solvent manufacturer s warnings Fluid hoses must have spring guards on both ends to protect them from rupture caused by kinks or bends at or close to the couplings Comply with all applicable local state and national fire electrical and other safety regulat...

Страница 5: ...r air valve upstream from the pump When it is closed and the pump air regulator 6a is opened the bleed type master air valve relieves all air pressure to the system components 4 Ventilate the spray booth To prevent hazardous concentrations of toxic and or flammable vapors spray only in a properly venti lated spray booth Never operate the spray gun unless ventilation fans are operating Check and fo...

Страница 6: ...ap 58 to secure the hose set to the leg of the cart This provides strain relief so that tugs on the heavy hoses don t damage the hose connections v Grounding the System To reduce the risk of static sparking ground the pump and all other equipment used or located in the spray area Check your local electrical code for detailed grounding instructions for your area and type of equipment Ground all of ...

Страница 7: ...lead and lag operation When triggered the gun emits air before the fluid is discharged When the trigger is released the fluid stops before the air flow stops This helps as sure the spray is atomized and prevents fluid buil dup on the air cap Loosen the air cap retaining ring G and rotate the horns of the air cap to obtain the desired spray position Tighten the retaining ring snugly but do not over...

Страница 8: ... sufficient volume of fluid without running too fast or too slow Trigger the gun while adjusting the needle valve Turn the needle valve handle IN clockwise to restrict fluid and slow down the pump Turn the needle valve handle OUT counterclockwise to allow more flow which speeds up the pump A CAUTION Never close the needle valve completely Doing so prevents circulation which can cause the fluid to ...

Страница 9: ...in the prepared fluid KEY A Bleed type master air valve C Air line 3 fluid heater 6 a Pump air regulator 6 b Gun air regulator 9 3 way valve 1 3 Drain hose 44 Fluid regulator 4 8 Filter drain valve 2 Hook the drain hose 13 on the waste pail 3 Close the filter drain valve 48 4 Turn the 3 way valve 9 to Drain 5 Open the fluid pressure regulator 44 fully clockwise 6 Turn the needle valve 5 ail the wa...

Страница 10: ...pressure reg ulator 4 until the straight fluid stream is within the range indicated for the viscosity of your fluid before it drops off See Fig 8 Make note of the pressure on the fluid gauge it is your optimal fluid pressure setting Fluid Viscosity Fluid Droop A Measured with 2 Zahn cup Light 18 25 seconds 8 10 200 250 mm Medium 25 40 seconds 6 8 150 200 mm Heavy 40 60 seconds 4 6 100 l 50 mm 0399...

Страница 11: ...rom the gun and clean sepa rately Do not reinstall at this time 3 Open the filter drain valve 48 Unscrew the fluid filter 45 bowl Remove the screen See manual 307 273 Reinstall the bowl without the screen 4 Hook the drain hose 13 on the waste pail 5 Turn the 3 way valve 9 to Drain 6 Turn the needle valve 5 all the way out counterclockwise 7 Put the suction tube 15 in a grounded pail with about 1 g...

Страница 12: ...h out some dirty sol vent Flush until the system is clean Repeat with clean solvent if necessary 17 18 19 Raise the suction tube out of the solvent trigger the gun and run the pump until air comes from the gun Turn the 3 way valve to Drain and run the pump until all air is expelled 20 Release the trigger and close the fluid regulator 44 and the air regulators 6a 6b Clean the filter screen air cap ...

Страница 13: ...90 ELBOW l 2 npt m x f 90 CORD GRIP ELBOW l 2 npt m includes nut washer and grommet Ref No Part No 25 100 840 26 111 805 28 188 093 29 169 971 30 103 473 3 1 155 494 32 101 754 33 107 219 34 100 639 35 108 290 36 100 021 37 100 015 38 100 016 4u 187 732 4 1 188 l 74 42 208 536 43 222 011 44 236 216 45 218 029 46 100 l 76 47 11 O 249 48 210 658 49 176455 50 5 1 52 53 54 54a 54b 55 56 57 58 60 6 1 6...

Страница 14: ...Parts 16 Model 237410 Series A 25 60 23 3 0 8 4 4 8 1 3 ...

Страница 15: ...Notes 14 3 0 8 4 4 8 ...

Страница 16: ...Notes c 308 448 15 ...

Страница 17: ...nction damage or wear caused by the incompatibility with Grace equipment of structures accessories equipment or materiais not supplied by Grace or the improper design manufacture installation operation or maintenance of structures accessories equipment or materials not supplied by Grace This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized G...

Отзывы: