Installation
333011D
11
Install the Gun
1. Loosen the manifold’s two set screws (29) and slide
the manifold (20) onto a 1/2 in. (13 mm) mounting
rod.
2. Position the gun and tighten the two set screws.
NOTE:
For added positioning reliability, insert a 1/8 in.
(3 mm) locating pin into the slot (NN) in the bracket and
through a hole in the rod. See the detail in F
IGURE
4.
Install the Pro Xp Auto Control
Module
The Pro Xp Auto Control Module is required for use with
smart models. To install a Pro Xp Auto Control Module,
see the module instruction manual 332989.
Connect the Air and Fluid Lines
F
IGURE
3 shows a schematic of air and fluid line connec-
tions, and F
IGURE
5 shows the manifold connections.
Connect the air and fluid lines as instructed below.
1. Connect the Graco Grounded Turbine Air Hose (B)
to the gun's turbine air inlet (TA) and connect the
hose ground wire (A) to a true earth ground (N). The
gun turbine air inlet fitting has left-hand threads to
prevent connecting another type of air hose to the
turbine air inlet.
2. Check the electrical grounding of the gun as
instructed on page 14.
3. Before connecting the high pressure fluid hose (P),
blow it out with air and flush it with solvent. Use sol-
vent which is compatible with the fluid to be
sprayed.
F
IG
. 4 Mounting Bracket
20
NN
8.00 in.
(203.2 mm)
2.88 in.
(73.2 mm)
To nozzle tip
29
To reduce the risk of electric shock, the turbine air
supply hose must be electrically connected to a true
earth ground.
Use only Graco Grounded Turbine
Air Hose.