Troubleshooting
28
3A6714C
Troubleshooting
1.
Follow
, page 15,
before checking or repairing.
Problem
Cause
Solution
Unit does not power on.
Incorrect/loose wiring
instructions,
page 6.
Tripped external fuse due to internal
component failure.
Contact Graco Customer Service.
Tripped external fuse from using
grease with an inadequate
temperature rating in a cold
environment.
Replace lubricant with a lubricant
rated for environmental conditions
and application.
Replace fuse.
Lubricant leaks past the seal located
on the bottom of the reservoir.
Seal was not installed correctly.
Replace seal.
Reservoir is being pressurized
during filling.
Ensure that the vent tube is not
plugged.
If the problem persists, contact
Graco Customer Service or your
local Graco distributor for
assistance.
The external controller is
functioning, but the unit is not
pumping during the ON cycle.
Motor failure.
Replace the motor.
The follower plate is not moving
downward.
Air is trapped in the reservoir
between the follower plate and the
lubricant.
Add grease following the
Purge any air from the reservoir.
After wiring and installing the
equipment, the pump is not working.
The pump is wired incorrectly.
Rewire the pump following
, page 9.