Non Controller Operation
3A6714C
19
Non Controller Operation
The pump can be controlled using an external, user sup-
plied, controller.
NOTE:
•
When using an external controller, Pump ON (Run)
Time should be set for no longer than 30 minutes.
•
In most cases, Pump OFF (Rest) Time should be
twice as long as Pump ON (Run) time. If alternative
ON / OFF times are required, contact Graco Cus-
tomer Service for assistance.
Low-Level Output Option
Models 25R800, 25R802, 25R807 and 25R809
Pumps without controllers include a Low-Level Output
Option. The low-level signal is monitored across PINS 4
and 5. For the locations and wiring information for PINS
4 and 5, see the
Wiring and Installation Diagrams
page 9.
Model 25R820, 25R822, 25R827 and 25R829
See the
Wiring and Installation Diagrams
Typical Low-Level Output Response with Low-Level Fluid
F
IG
. 22