6
306674U
Installation
Mount the pump to suit the type of installation planned.
Very heavy lubricants may require an inductor plate.
See page 18 for the mounting hole layout and dimen-
sions
Install the air line accessories in the approximate order
shown in the Typical Installation. Install a bleed-type
master air valve (B) within easy reach of the pump,
upstream from the air regulator. Install an air filter (C)
to remove harmful dirt and moisture from your com-
pressed air supply. For automatic air motor lubrication,
install an air line oiler (D) close to the pump air inlet.
Install an air regulator (E) to control pump speed.
WARNING
A bleed-type master air valve (B) is required to
shut off and relieve air pressure that may be
trapped in the air motor. Trapped air could cause
the pump to cycle unexpectedly and cause serious
bodily injury, including amputation.
Be sure the air hose is properly sized to deliver an
adequate supply of air to the motor. Refer to the
Technical Data on page 19.
Connect a dispensing hose to the 3/8 npt(f) pump
outlet. Install an appropriate gun or dispensing valve to
the hose.
Ground the pump as explained on page 5.
Fig. 2
Key
A
B
C
D
E
F
G
H
J
Grounded Air Line
Bleed-type Master Air Valve
Air Filter
Air Line Oiler
Air Regulator
Grounded Dispensing Hose
Dispensing Valve
Elevator Assy. With Inductors
Ground Wire
Typical Installation
06309
A
B
C
D
E
H
J
F
G