Basic Troubleshooting /
基本故障排除
/
기본적인 문제 해결
40
333119D
Low Fluid Output
1.
Worn or clogged spray tip.
Relieve pressure
, page 19. Replace or clean tip.
Refer to gun instruction manual, 313347.
2.
Verify pump does not continue
to stroke when gun trigger
is released.
Service
Pump
, page 60.
3.
Prime valve leaking.
Relieve pressure
, page 19. Then repair
Prime
Valve
, page 62.
4.
Suction hose connections.
Tighten any loose connections. Check o-rings
on suction hose tube.
5.
Electric supply with volt meter.
Meter must read 105-130 Vac for
110-120 Vac models and 210-255
for 240 Vac models. Low voltages
reduce sprayer performance.
Reset building circuit breaker; replace building fuse.
Repair electrical outlet or try another outlet.
6.
Extension cord size and length.
Replace with a correct, grounded extension cord,
page 16.
7.
Leads from motor to circuit
board for damaged or loose
wire connectors. Inspect wiring
insulation and terminals for signs of
overheating.
Be sure male terminal pins are centered and firmly
connected to female terminals. Replace any loose
terminals or damaged wiring. Securely reconnect
terminals.
8.
Worn motor brushes which must
be 1/4 in. (6 mm) minimum.
Replace
Motor
, page 36.
9.
Motor brushes binding in brush
holders.
Clean brush holders. Remove carbon dust by using
compressed air to blow out brush dust.
10. Low stall pressure. Turn pressure
control knob fully clockwise.
Replace
Pressure Control Assembly
, page 62.
11. Motor armature for shorts by using
an armature tester (growler) or per-
form spin test, page 56.
Replace
Motor
, page 36.
12. Pump is primed.
Prime pump, page 22.
13. Inlet and outlet balls are not stuck.
Inlet:
Remove suction tube and place pencil into inlet
housing to dislodge ball and allow proper priming.
Outlet:
Insert screwdriver in slot and remove
Easy-Access door, page 15. Unscrew outlet valve
with a 3/4 in. socket. Remove and clean assembly.
Problem
What To Check
(If check is OK, go to next check)
What To Do
(When check is not OK, refer to this column)
Содержание FinishPro II 295
Страница 7: ...333119D 7 WARNING WARNING WARNING WARNING 120 230 3 3 3 12 AWG 2 5 120V US 230V...
Страница 8: ...8 333119D WARNING WARNING WARNING WARNING Graco 3 2 MSDS 20 6 m...
Страница 9: ...333119D 9 Graco 3300 227 22 7 3300 227 22 7 Graco Graco 25 WARNING WARNING WARNING WARNING...
Страница 10: ...10 333119D 1 1 1 MSDS 65 WARNING WARNING WARNING WARNING...
Страница 11: ...333119D 11 WARNING WARNING WARNING WARNING 120V 230V 3 12 AWG 2 5mm2 120V US 230V...
Страница 12: ...12 333119D WARNING WARNING WARNING WARNING Graco 3 2 MSDS 20ft 6m 3...
Страница 13: ...333119D 13 Graco 3300psi 227bar 22 7MPa 3300psi 227bar 22 7MPa Graco Graco 25ft WARNING WARNING WARNING WARNING...
Страница 14: ...14 333119D 1 1 1 MSDS 65 WARNING WARNING WARNING WARNING...
Страница 43: ...333119D 43 Graco 1 2 19 313347 1 62 2 62 36 1 ON 2...
Страница 47: ...333119D 47 38 62 62 62 62 57 62...
Страница 48: ...48 333119D Graco 1 2 19 313347 1 62 2 62 36 1 ON 2 ON OFF...
Страница 51: ...333119D 51 1 62 2 3 4 O 5 60 6 62 7 62 8 62 1 115 F 46 C 2 36 1 2 3 4...
Страница 52: ...52 333119D 1 ON 2 110 120 Vac 105 Vac 240 Vac 210 Vac 3 4 5 0 6 65 7 115 F 46 C 8 65 1 2 3 19 313347 1 257824...
Страница 53: ...333119D 53 38 62 62 62 62 57 62...