background image

           Air Solenoid (N/O).
Closed when the compressor is on.
Open when compressor is off.
With the solenoid open,  the air 
pressure will exhaust and allow the 
compressor to start.

Exhaust Port

   Air Hose 
Connection

           32psi. Pressure 
               Relief Valve.
The valve will open when the
compressor builds over 32psi. 
    This is a normal function. 

NO

YES

NO

Replace the 

  compressor.

Is the compressor

  trying to start? 

    (Humming)  

NO

YES

 Have the steps been 

      followed in the  

 (Air Compressor will 

     not start) section?

 See (Air Compressor 

 will not start) section?

 Disconnect the air hose 

    from the air solenoid. 

 Turn the compressor on.

Dose the compressor start.

Replace the 

  air solenoid.

YES

YES

  The compressor is ok.

NO

    Is there air coming 

         out of the air 

           Pressure 

        Relief Valve?

 

YES

Repair or replace 

       Pressure 

   Relief Valve? 

  

  

YES

 Is there air coming 

     out of the air 

 solenoid exhaust?

 

Repair or replace 

the air compressor. 

  

Repair or replace 

  the air solenoid. 

  

NO

NO

  

                                 390 Finish

Pro

 

  Air Compressor runs but will not build pressure.

Connect a test air gauge 

to the air hose connector.

   Start the compressor.

    Do you have 32psi?

  

17

Содержание Finishpro 390

Страница 1: ...be used by a qualified Service Technician FinishPro 390 395 Airless Air Assisted Sprayer Repair Electrical Manual Black Red Yel Yel 3 00 First choice when quality counts ti9026a FinishPro 395 FinishPr...

Страница 2: ...ir Compressor Air Compressor will not start 16 Air Compressor runs but will not build pressure 17 Air Compressor is trying to start humming 10 FinishPro 395 ON OFF Switch Test 18 19 Switch Ladder Diag...

Страница 3: ...power source to the load Current is measured in AMPERES AMPS A or I See Figure 1 NOTE Meter is only clamped around one wire VOLTAGE Voltage is the force that causes current to flow in a circuit Volta...

Страница 4: ...tion to the flow of current in a circuit Resistance is used to control the amount of voltage and or amperage in a circuit Resistance is measured in OHMS See Figure 3 A common component check would be...

Страница 5: ...you if the wire or component is capable of conducting current Continuity testers are available at almost any hardware store A volt ohmmeter or VOM can also be used to check continuity This meter can...

Страница 6: ...load voltage A good piece of wire will carry line and load voltage Damaged Fragmented Wire Damaged Fragmented Wire Pinched Wire 120 Vac input static voltage and drops to 76Vac load voltage Other caus...

Страница 7: ...VOM leads to several bare metal surfaces on the body of the machine If the light or meter indicates continuity the machine is properly grounded If the light or meter doesn t indicate continuity trace...

Страница 8: ...remove the capacitor s If capacitor s are attached to the control board the test can not be perormed 3 SEE ABOVE WARNING Using a screwdriver with insulated handles hold so that the blade contacts the...

Страница 9: ...fective If the meter beeps go to the next step 3 Connect test leads as shown in Figure C If the meter beeps the rectifer is defective If the meter does not beep go to the next step 4 Connect test lead...

Страница 10: ...ES Check the connector for the white wires If ok repair or replace the power Cord Replace the power switch Switch is good Proceed to the proper Test Section NO See step 3 Do you have over 100 AC volts...

Страница 11: ...or Power Cord F1 Control Board Airless OFF Air Assisted Airless Mode Switch Down Air Assisited Mode Switch Up Off Switch Center FinishPro 390 Switch Ladder Diagram White White White White White White...

Страница 12: ...res See step 5 Does the motor run See Motor Test YES See step 1 Do you have over 100 AC volts YES See step 3 Is there over 100 DC volts YES YES See ON OFF Switch Test NO Replace Pressure Switch Replac...

Страница 13: ...AC Volts 110 120AC V BEEP Checking the motor thermistor switch Unplug the motor wires from control board Carefully insert the meter probes into the 2 yellow wires Meter should read continuity Note mo...

Страница 14: ...start the motor If motor does not run follow the steps below Step 1 Step 2 Step 4 Checking the motor wires for a short Put the meter lead on the motor case Move the meter lead to each wire Meter shoul...

Страница 15: ...once material comes out the prime drain hose turn the prime spray valve to spray Does fluid continue to flow though the drain hose Check the Inlet and Out valves for a stuck ball See freeing up inlet...

Страница 16: ...Cord plugged in Meter on AC Volts Compressor AA Mode Airless Mode Off Step 1 J4 Control Board 110 120AC V J3 Connector Power Plug To NO See step 1 Do you have over 100 AC volts YES Does the airless m...

Страница 17: ...he Air Compressor will not start section See Air Compressor will not start section Disconnect the air hose from the air solenoid Turn the compressor on Dose the compressor start Replace the air soleno...

Страница 18: ...ts NO YES Replace the power switch See step 5 Do you have Continuity NO Replace the power switch FinishPro 395 ON OFF Switch Test Switch is good Proceed to the proper Test Section YES Airless Motor wi...

Страница 19: ...gged from switch Meter should show continuity or Beep FinishPro 395 ON OFF Switch Test Compressor Power Cord AA Mode Airless Mode Off Step 1 Power switch in the Airless Mode Cord plugged in Meter on A...

Страница 20: ...ack Black Power Cord Compressor Air Assisted Control Board White Blue Brown Black Black Power Cord Compressor White White White Brown Brown Brown Blue Blue Blue FinishPro 395 Switch Ladder Diagram Air...

Страница 21: ...ive thermistor switch YES NO See step 3 Is there continuity through the thermistor wires See step 4 Does the motor run See motor test section See Error Codes YES NO See step 1 Do you have over 100 AC...

Страница 22: ...gh Meter on DC volts Motor Step 2 Thermistor Wires to motor BEEP Checking the motor thermistor switch Unplug the J11 2 white wires from control board Meter should read continuity Note motor should be...

Страница 23: ...re knob clockwise a turn Try to restart the motor If motor does not run follow the steps below Step 1 Step 2 Step 4 Checking the motor wires for a short Put the meter lead on the motor case Move the m...

Страница 24: ...nce material comes out the prime drain hose turn the prime spray valve to spray Does fluid continue to flow though the drain hose Check the Inlet and Outlet valves for a stuck ball See freeing up inle...

Страница 25: ...l Cord plugged in Meter on AC Volts 110 120AC V Blk Green Blk Yellow Blue White Blk Brn Grn Yel N L N Compressor Power Cord AA Mode Airless Mode Off Step 2 Power switch in the AA Mode Blk meter led on...

Страница 26: ...re Relief Valve Replace the Air Regulator NO YES YES Connect a test air gauge to the air hose connector Start the compressor NO Replace the compressor Is the compressor trying to start Humming NO YES...

Страница 27: ...nt on Control is commanding motor to run Blinks 2 x repeatedly High pressure signal from transducer Blinks 3 x repeatedly Transducerfailure or connection error Blinks 4 x repeatedly Excessive Wall vol...

Страница 28: ...sprayer ON and control knob to turn clockwise If ok replace pot Replace control board if sprayer still does not run But first verify transducer and connections are ok See next page OR Short center pin...

Страница 29: ...etal braid in x 50 ft minimum Smaller hose or metal braid hose may result in high pressure spikes 4 Set sprayer to OFF and disconnect power to sprayer 5 Check transducer connections to control board 1...

Страница 30: ...control board socket Check that transducer and control board contacts are clean and secure 4 Reconnect transducer to control board socket Connect power set sprayer ON and control knob to turn clockwis...

Страница 31: ...l board status light blinks 4x repeatedly What does this mean Voltage applied to the sprayer is too high Troubleshooting Procedure 1 Make sure the sprayer is plugged into the proper AC power source Le...

Страница 32: ...ck for locked or frozen pump or drive train If sprayer does not run go to next step 2 Set sprayer to OFF and disconnect power to sprayer 3 Disconnect motor connector s from control board socket s Chec...

Страница 33: ...oard Set sprayer to OFF and disconnect power to sprayer 2 Disconnect motor thermal switch wires from control board Check that all connections at the control board are clean and secure 3 If connections...

Отзывы: