Fig. 7
2
1
6a
6b
6c
6e
2
G
E
F
washers & nuts
4
B
Install ground wire 222011 (required)
here. See Fig. 1 on page 9.
6d
5
hold-down clamp
03397C
03397D
308382 15
Installation
Model 244094, 16-Gallon (60 Liter) Economy Portable Dispenser
1.
Assemble the base (5) as shown in Fig. 7. Place
an opened 16-gallon (60 liter) drum of oil on the
base, and secure it with the hold-down clamps.
Tighten the hold-down clamp bolts.
2.
Set the cover (4) on a 16-gallon (60 liter) drum and
secure with the thumbscrews (G). Install the pump
(1) on the cover (4) with the screws (E), washers
and nuts (F) supplied.
3.
Install the seal nut (6d), nipple (6c), and meter (6e)
in the fluid outlet (B) of the pump (1). Connect the
hose (6a) to the meter outlet, then assemble the
dispense valve (6b) to the hose.
Содержание FALCON 244085
Страница 7: ...308382 7 Notes...
Страница 23: ...308382 23 Notes...