14 308382
Installation
Model 244089, 275-Gallon (1040 Liter) Tank Bung-Mount Pump
1.
Screw the bung adapter (C) into the bung hole of
the tank. Adjust the pump so its intake is about 1
in. (25 mm) off the bottom of the tank, then tighten
the bung adapter screw (D) to hold the pump in
position. See Fig. 6.
2.
Assemble the air regulator kit (items 3a–3d) to the
pump air inlet (A), as shown. Use thread sealant
and tighten all parts securely.
3.
Apply thread sealant to the male threads of the 3/8
npt swivel union (2b). Screw the union into the
bleed-type master air valve (3c).
4.
Apply thread sealant to the male threads of the 1/2
npt swivel union (2d). Screw the union into the
pump fluid outlet (B).
5.
Connect the 1/2 npt(mbe) fluid hose (2c) to the
swivel union (2d).
6.
Connect the 3/8 npt(mbe) air hose (2a) to the
swivel union (2b).
Fig. 6
3a
3b
3c
3d
2a
2b
2c
2d
1
2
1
B
A
1
Apply thread sealant.
C
D
Install ground wire 222011 (required)
here. See Fig. 1 on page 9.
2
1
1
1
Thermal Relief
Kit 235998
(recommended)
1
03396B