Installation
6
332511B
Installation
Grounding
Ground the system as instructed within this manual.
1. Access the Platen
a. Perform
Change Drums
procedure in the
Air-Powered Ram manual. Do not load a new
drum.
b. Perform
Shutdown
procedure in the Exacta
Blend AGP Advanced Glazing Proportioner,
Setup-Operation manual.
c. Thoroughly clean all material that may be found
on the top of the platen.
d. Turn off all sources of power to the machine.
To avoid serious injury or machine damage, all
electrical connections need to be done by a qualified
electrician in compliance with local codes.
The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.