Technical Specifications
US
Metric
Maximum air input pressure
100 psi
7 bar, 0.7 MPa
Maximum inlet feed pressure*
70 psi
4.8 bar, 0.48 MPa
Maximum fluid working pressure
400 psi
28 bar, 2.8 MPa
Maximum static fluid pressure
430 psi
30 bar, 3.0 MPa
Ratio
4:1
Maximum recommended continuous
cycle rate
20 cycles per minute
Volume per cycle (double stroke)
4D150
5 oz per cycle
150 cc per cycle
4D350
12 oz per cycle
350 cc per cycle
Ambient and operating temperature
range. Use dry compressed air when
operating at low temperatures.
32 to 122°F
0 to 50°C
Dry suction lift
23 ft
7.0 m
Wet suction lift
29 ft
8.8 m
Air inlet size
4D150
1/4 npt
4D350
1/2 npt
Fluid inlet size
4D150
1 in. Tri-Clamp Flange, 1/2 in npt, or 1/2 in bspp
4D350
1 in. Tri-Clamp Flange, 3/4 in npt, or 3/4 in bspp
Fluid outlet size
4D150
1 in. Tri-Clamp Flange, 1/2 in npt, or 1/2 in. bspp
4D350
1 in. Tri-Clamp Flange, 3/4 in npt, or 3/4 in. bspp
Weight (approximate)
4D150
31 lb
14 kg
4D350
72 lb
33 kg
Wetted parts
stainless steel, perfluoroelastomer (FFKM), PTFE, Polyphenylene
Sulfide (PPS)
* NOTE: When pressure feeding the pump inlet, do not allow the outlet pressure to exceed the Maximum
Fluid Working Pressure. The inlet feed pressure will pressurize the outlet by the corresponding amount.
Example: Pressure feeding the inlet with 60 psi and supplying 80 psi air pressure will result in the following:
80psi*4:1+60psi = 380psi fluid pressure.
40
333015E
Содержание Endura-Flo 4D150
Страница 9: ...Installation Notes 333015E 9...
Страница 30: ...Parts Parts 30 333015E...
Страница 33: ...Parts Air Valve Parts Figure 2 333015E 33...